background image

 

ERIS3000 

18

 

Storage

 

Built-in HDD

 

Up to 2 built-in SATA HDDs 

Export

 

USB

 

USB 2.0 CD / RW (Optional) 

USB Thumb Drive 

Support 

Alarm 

Alarm Input 

X4, Terminal   

X8, Terminal 

X16, Terminal 

Alarm Detection 

N.C./N.O., Programmable 

Alarm output   

N.C/N.O, programmable 3.0 A / 30 VDC or 3.0 A / 125 VAC 

Auditory Alert   

Built-in Buzzer   

Motion Detection   

16x12 

Video Loss Detection 

Programmable 

External I/O Board 

(Optional) 

Terminal Block (2 x 6) 

Terminal Block (4 x 6) 

Communication

 

Communication Protocol 

RS-485 DSCP 

Remote Control Software

 

CMS, Remote Software/Browser 

Network Connectivity

 

Ethernet RJ-45 connector, 10/100Mbps, supports DHCP 

LAN Remote Control 

IE Browser, Windows AP 

Dome Camera Control 

Protocol 

DynaColor, Pelco P, Pelco D, AD422, Fatrax 2, Panasonic 

Remote Operation 

Monitor, Playback, Recording, System Setup, Dome Camera Control 

On-Screen Display

 

Search 

Based on Time or Event 

Play/Pause/REW/FF 

Control Playback Direction & Speed 

Password Control 

2 Level, Administrator / User 

General

 

Unit Dimension (WxHxD)

 

440 x 55 x 413 mm (17.3 x 2.2 x 16.3 inches) 

Unit Weight 

4.9 kg (10.8 lbs) 

Operation Temperature 

0°C - 40°C (32°F - 104°F) 

Relative Humidity

 

5% - 85% Non-condensing 

Power Consumption & 

Input

 

ERIS BASIC 4/8/16 19W/30W/34W Ext. Adapter, AC 100 ~ 240V to DC12V

ERIS ADVANCED 4/8/16 50W/61W/65W 110-230V select able   

 

 

Summary of Contents for ERIS 3000 ADVANCED

Page 1: ...es DVR is properly delivered Remove all items from the box and make sure the box contains the following items ERIS 3000 BASIC Power Adapter Software CD CMS User Guides PDF User s manual Rack mount ear...

Page 2: ...ction keys and zoom Enter Back up Call Monitor setup Split screen mode on main monitor Play Stop Pause Freeze Sequence setup Menu Setup Search Alarm In Rs485 Alarm Out VGA Out Audio Out Main out Compo...

Page 3: ...ameras in sequence The BNC Call Monitor connector allows the user to connect the DVR to a call monitor Video System Switch This switch is used to set the unit to PAL or NTSC Alarm I O RS 485 The unit...

Page 4: ...4 4 Alarm In 5 16 Alarm In 13 5 Alarm In 4 17 Alarm In 12 6 Alarm In 3 18 Alarm In 11 7 Alarm In 2 19 Alarm In 10 8 Alarm In 1 20 Alarm In 9 9 RS485 D 21 RS485 D 10 Common Node 22 Ground 11 Normal Ope...

Page 5: ...after the changes are confirmed To setup the Date Time using the Time Sync function Select Date Time in System Setup menu to enter the Date Time menu Select Time Zone to enter the time zone To find o...

Page 6: ...ERIS3000 6 Protocol Setup will not be accessible...

Page 7: ...rnet connection without a dialup modem It requires an Ethernet connection to a network The default ID of your ERIS DVR series must be changed to avoid network conflicts From Main menu select System Se...

Page 8: ...vailable protocols include DynaColor Pelco D Pelco P AD422 Fastrax 2 JVC Panasonic_C Panasonic_N and None default Note that ID number must match the ID address defined by the dome camera To configure...

Page 9: ...l Move the cursor to Event List and press ENTER to list the event video of the selected channels The list displays each event by date time triggered camera and alarm type The latest recorded event vid...

Page 10: ...is not unzipped correct the ERIS can not find the update Software upgrade via USB Press MENU button to enter the menu Enter Admin Password Default 1 2 3 4 Press ENTER Select SYSTEM SETUP and press ENT...

Page 11: ...ct Tools from the main menu of the browser then Internet Options and then click the Security tab Select Trusted sites and click Sites to specify its security setting Uncheck Require server verificatio...

Page 12: ...r Browser type in the IP address of your ERIS The Login window opens Default User name is admin Default Password is 1234 Make sure you change it and make sure you store the new password in a safe plac...

Page 13: ...d 16 video windows Down load player by selecting this symbol To enter the menu in a Speed Dome PELCO protocol Call preset 95 The menu appears on the screen Move around with the direction keys To enter...

Page 14: ...m the Start field You can change the date and time either by typing desired numbers directly or using the arrow buttons Click OK to start the playback or click Close to abort To Playback Local drv Fil...

Page 15: ...ize of the hard drive In the menu you can Remote Configure ERIS To Playback Event Video Click SEARCH on the main window toolbar The Event List appears Scroll through the Event List and highlight the i...

Page 16: ...ERIS3000 16 Remote Controller A remote control is provided for the DVR unit The function keys on the remote control are listed as below figure...

Page 17: ...1 Line Out Recording Mode Always Real time Record Synchronized with Video Compression Method ADPCM G 726 Data Rate 4 KB s per channel Operation VCR mode Playback Only for Video Original Speed Recordin...

Page 18: ...Network Connectivity Ethernet RJ 45 connector 10 100Mbps supports DHCP LAN Remote Control IE Browser Windows AP Dome Camera Control Protocol DynaColor Pelco P Pelco D AD422 Fatrax 2 Panasonic Remote O...

Page 19: ...cuda 7200 9 ST3400633A 400G Barracuda 7200 9 ST3300622A 300G Barracuda 7200 9 ST3250824A 250G Barracuda 7200 9 ST3160812A 160G Barracuda 7200 10 ST3750640A 750G Barracuda 7200 10 ST3320620A 320G Barra...