Use the switch to change your speed dome ID by turning the arrow to the desired
number respectively. For instance, if the speed dome ID is 123, the ID switch
should be set as below:
centesimal decimal
single digit
NOTE:
No two speed domes should be given the same ID, or
communication conflict may occur.
NOTE:
The number “0” should locate upwards as shown in
above diagram for correct switch definition.
4.
Dome Control Protocol
Protocol is a specific set of rules, procdures used for data communications.
Basing on the protocol of your management software that you are going to use.
Use the switch to set your dome control protocol and the baud rate. Refer to
table below and turn the arrow to choose a protocol for your speed dome.
Switch No.
Protocol
Baud Rate
01
Pelco D
2400
02
Pelco P
4800
07
Dynacolor 9600
11
Pelco D
4800
12
Pelco D
9600
13
Pelco P
2400
14
Pelco P
9600
Select protocol: Pelco D, with switch no. 01 and baud rate 2400, for instance, the
ID switch should be set as below:
decimal single digit
5.
16 Pin Connector for LAN/WAN
The LAN/WAN cable (shown as the figure below) is shipped with IP high
speed dome. Please find it in the accessory bag.