8.
Error message
NAK
Reasons for a error message
• command is unknown
• datas lies out of the valid value range
• datas are wrong (to short or to long)
• the instrument SSI 9001/2 is in the programming mode
(Each command is receipt with a NAK, when the instrument is in the programming
mode)
8.1.
Error word register
Read the error word register
SOH
D
D
STX
E
R
R
ETX
BCC
Answer of SSI 9001/2
STX
X
X
X
ETX
BCC
Explanation of error word register
Error word register
Significance
0
no error
10
command unknown
11
datas are wrong (to shortz)
12
datas are wrong (to long)
13
datas contains wrong signs
14
datas lies out of the valid value range
15
wrong control byte
A error word be preserved as long as the error word register is read through. After
the reading the error word register is cleared.
8. Error message NAK
35
ERMA-Electronic GmbH