WARNING. Prior to connecting any appliance to the generator, check the rating label of the appliance. The generator is
rated at 1600W so if the appliance being connected is higher than 1600W, the protective cut out may switch the generator
off to prevent over load damage to the generator. The generator will withstand short operation up to 1800W for a maximum
of 20 minutes.
Note. Motorized products will require more energy upon start up and products, which are rated below 1600W, may not start
if the starting current is excessive, this is not due to a performance fault of the generator.
22
、
DC Applications
The DC output should only be used for recharging 12-volt automotive lead acid type batteries, and do not charge batteries
while they are connected to a vehicle. Make sure they have been totally disconnected prior to connecting to the generator
for recharging.
Note. Only use the DC leads provided with this
generator, when using the DC output.
When charging a battery the following instructions need to
be followed:
1. Disconnect the original leads from the battery.
2. Fully loosen the battery fluid filler caps.
3. Fill the battery cells with distilled water to the upper limit if
the battery is empty.
4. Measure the specific gravity fluid by using a hydrometer
and calculate the charging time in accordance with the
table shown (Fig.O).