8.5.
Programming level of serial interface P-04
The parameters of the programming level P-04 exists only by panel meters with the
option serial interface. The interface moduls are bidirectional and works at the slave
mode.
Param.
Description
Setting range
Default
values
4-00
Interface address
0 .. 31
1
4-01
Interface baud rate
0 ->
: 300 baud
1 ->
: 600 baud
2 ->
: 1200 baud
3 ->
: 2400 baud
4 ->
: 4800 baud
5 ->
: 9600 baud
6 ->
: 19200 aud
0 .. 6
6
4-02
Transmission-Mode
0 ->
PC-Mode
1 ->
Terminal-Mode timer controlled
2 ->
Terminal-Mode button/input controlled
0 .. 2
0
4-03
Sendrate in sec.
0 ->
permanent transmission
0 .. 3600
0
4-04
Data source for serial interface
0 ->
Value of encoder
1 ->
MAX value
2 ->
MIN value
3 ->
Hold value
0 .. 3
0
4End
Leave programming level P-04
The meter can be controlled completly with the serial interface. That means the panel
meter can initialized of a host (unit name, revision number). It can be adjust all
parameters and it can be read all measured values resp. all values of the parameters.
8.5.1. Transmission-Mode
PC-Mode
In PC-Mode a single transmission is started with a special command from the PC.
A complete list of all possible commands is available as additional manual.
8. Procedure of programming
23
ERMA-Electronic GmbH