PROXIMITY CARD MANAGEMENT

• The 

fi

 rst key fob programmed will become the Master Key Fob 

(supplied and pre-programmed with kits)

•  The Master Key Fob will then be used to program all 

subsequent key fobs going forward

•  To enter programming mode a Master Key Fob must be used
•  Maximum of 10 key fobs per station

Where is the RFID Reader?

•  The RFID Reader is situated directly behind Call Station 1 name 

plate  

Adding user key fobs

•  Hold the Master Key Fob to the panel RFID Reader 
•  During the door opening process hold the next key fob to the 

panel. (You will be automatically entered into Programming 
Mode at this point)

•  Hold new key fob to RFID Reader until an audible beep is heard 

to con

fi

 rm card acceptance 

•  Repeat holding key fobs to panel RFID

If an unregistered key fob is used at the panel a short triple beep sound 
will be emitted

Exiting Programming Mode

•  Programming Mode will time out after 5 seconds of no activity

Deleting key fobs from an allocated call station

•  Hold Master Key Fob to Panel activating door unlocking process
•  Immediately press and hold relevant call station for 4 seconds
•  A loud beep will be emitted for about 10 - 15 seconds
•  When it stops the call station has been cleared of all key fobs 

including Master Key Fob

•  This can be con

fi

 rmed by holding Master Key Fob to the panel - 

as now unregistered you will hear 3 short beeps

Deleting individual key fobs is only possible via the software

Creating a Master Key Fob

•  Panel must be o

 

•  Press and hold the 

fi

 rst call button

•  Turn power on > a loud continuous beep will sound
• Take your 

fi

 nger o

  the call button 

•  Hold and place an unregistered key fob to the RFID Reader 
•  You will hear the beep stop for a split second then a second 

short beep will sound

•  The Master Key Fob is now programmed

Supply voltage

15VDC ± 5%

Power consumption in standby mode

~ 2.5W

Maximum power consumption

400mA

Electric strike supply voltage

12VDC - 15VDC

Permissible electric strike output load

1.5A

Output type

Normal or reversing (default: 

normal)

Lock activity time

0.6 to 25s (default: 4s)

Output control type

Pulse to the electric strike (default) 

or constant to the relay

Camera angle

About 75º

Camera adjustment angle

Vertical and horizontal 20º

Connector type

RJ45 socket / removable ARK 

screw connectors

Panel front material

Stainless steel

External input impedance for opening 

(INPUT)

 20

Ω

, input type: normally open 

(NO)

INPUT activation delay time

0 - 25s (default: 0s)

Panel front dimensions

286 x 90 mm (height x width)

Proximity RFID Standard

Unique 125KHzs

maximum number of supported 

proximity cards 70

10 for pr 10 

administrative ones

COMO PRO Technical Speci