PROXIMITY CARD MANAGEMENT
• The
fi
rst key fob programmed will become the Master Key Fob
(supplied and pre-programmed with kits)
• The Master Key Fob will then be used to program all
subsequent key fobs going forward
• To enter programming mode a Master Key Fob must be used
• Maximum of 10 key fobs per station
Where is the RFID Reader?
• The RFID Reader is situated directly behind Call Station 1 name
plate
Adding user key fobs
• Hold the Master Key Fob to the panel RFID Reader
• During the door opening process hold the next key fob to the
panel. (You will be automatically entered into Programming
Mode at this point)
• Hold new key fob to RFID Reader until an audible beep is heard
to con
fi
rm card acceptance
• Repeat holding key fobs to panel RFID
If an unregistered key fob is used at the panel a short triple beep sound
will be emitted
Exiting Programming Mode
• Programming Mode will time out after 5 seconds of no activity
Deleting key fobs from an allocated call station
• Hold Master Key Fob to Panel activating door unlocking process
• Immediately press and hold relevant call station for 4 seconds
• A loud beep will be emitted for about 10 - 15 seconds
• When it stops the call station has been cleared of all key fobs
including Master Key Fob
• This can be con
fi
rmed by holding Master Key Fob to the panel -
as now unregistered you will hear 3 short beeps
Deleting individual key fobs is only possible via the software
Creating a Master Key Fob
• Panel must be o
ff
• Press and hold the
fi
rst call button
• Turn power on > a loud continuous beep will sound
• Take your
fi
nger o
ff
the call button
• Hold and place an unregistered key fob to the RFID Reader
• You will hear the beep stop for a split second then a second
short beep will sound
• The Master Key Fob is now programmed
Supply voltage
15VDC ± 5%
Power consumption in standby mode
~ 2.5W
Maximum power consumption
400mA
Electric strike supply voltage
12VDC - 15VDC
Permissible electric strike output load
1.5A
Output type
Normal or reversing (default:
normal)
Lock activity time
0.6 to 25s (default: 4s)
Output control type
Pulse to the electric strike (default)
or constant to the relay
Camera angle
About 75º
Camera adjustment angle
Vertical and horizontal 20º
Connector type
RJ45 socket / removable ARK
screw connectors
Panel front material
Stainless steel
External input impedance for opening
(INPUT)
≤
20
Ω
, input type: normally open
(NO)
INPUT activation delay time
0 - 25s (default: 0s)
Panel front dimensions
286 x 90 mm (height x width)
Proximity RFID Standard
Unique 125KHzs
maximum number of supported
proximity cards 70
10 for pr 10
administrative ones