erkodent Erkopress CI Motion Instructions Manual Download Page 5

4

Compressed air connection and 

pressure regulator 

(only Erkopress _ motion) 

Medium-wave infrared heater 

Touchpanel 

Main switch 

Insertion ramp for foil reception 

 

Fixation for foil frame

Sensor window 

Form pot

Insertion rail for the form pot

Granules collecting device

Mains connection (at the side)

Erkopress _

motion 

+

 

Erkopress ci 

motion

Technical data:

Dimensions: 

Erkopress    _ motion   

ci motion

 

Height   

320 mm   

320 mm

 

Width   

350 mm   

350 mm

 

Depth   

430 mm   

430 mm 

 

Weight   

18.9 kg   

21.3 kg

Electricity: ~220 - 240 (100,110 - 120) volts, 50 - 60 hertz   

 

max. 

 

380 watt   

440 watt

Fuse:   230/240 V  

2 x T-2 A   

2 x T-2.5 A

 

100/115 V  

2 x T-4 A    

2 x T-5 A

Heater: medium-wave infrared heater, 280 watt

Temperature sensor: touchless infrared sensor,  

measuring range up to 240 °C

 

Foil dimensions: Ø120 mm, thickness 0 - 5.5 mm
Form pot inner dimensions: Ø 101 mm, height 44 mm

Erkopress_ motion

, operating pressure 3 - 6 bar, 

required mains system pressure > 6 bar, 

pressure regulator, factory setting 4.5 bar,

noise level < 70 dB(A) at 30 cm distance

Erkopress ci motion

 with integrated compressor 

and reserve compressed-air, operating pressure up

to 6 bar, noise level < 70 dB(A) at 30 cm distance

Pressure regulator, only Erkopress   motion:

The operating pressure of the Erkopress motion device can be set between 3 and 6 bar, 

the factory setting is 4.5 bar.

Increase or decrease pressure:
• Pull up the pressure regulator head

• Select operating pressure (3 - 6 bar)

• Press the pressure regulator head back

Summary of Contents for Erkopress CI Motion

Page 1: ...Erkopress _motion Erkopress ci motion Instructions...

Page 2: ...n The unit should only be cleaned with a damp cloth Do not use any solvents or other cleaning agents Maintenance see page 12 Repairs of the units must only be carried out by trained personnel using or...

Page 3: ...ellen Version entspricht Richtlinie Maschinen 2006 42 EG EMV Richtlinie 2014 30 EU DIN EN 12100 Sicherheit von Maschinen EN 13849 1 Sicherheitsbezogene Teile von Steuerungen DIN EN ISO 14120 Sicherhei...

Page 4: ...k pressure hose c Support bracket d Brass nut Installation Push the black pressure hose into the compressed air connector at the pressure regulator 1 Arrangement 2a Fasten the support bracket c to the...

Page 5: ...A Heater medium wave infrared heater 280 watt Temperature sensor touchless infrared sensor measuring range up to 240 C Foil dimensions 120 mm thickness 0 5 5 mm Form pot inner dimensions 101 mm height...

Page 6: ...ure abort favourites delete change presettings special functions heating on add favourite new foil heating off foil thickness language selection move support for foil reception continue refer to instr...

Page 7: ...on fields on slight pressure For input the enclosed brush for granules is equipped with a rubber cap However input is also possible with fingers Basic display Select language for any further use of th...

Page 8: ...d cooling time save as favourite menu OK next step one step back Change factory settings for a foil The rated temperature and the cooling time can be changed for one single thermoforming process or co...

Page 9: ...vourites After the desired foil is selected from the list of foils the display shown at point 1 will be visible To save the foil as favourite select to favourites Recommendation If an Erkodent foil wi...

Page 10: ...the heater that it clicks into place The foil temperature appears in the display the foil is heated The function field X interrupts the heating process and leads back to the display 1 If the foil is...

Page 11: ...rature and cooling time have to be determined using the special functions page 9 The new foils can be saved in the list of favourites and selected via this list Note Max 240 C can be entered as rated...

Page 12: ...the foil is ready for thermoforming illustration The heating switches off if the foil is pulled out of the heating area heating out is selected or if the sensor measures 240 C The temperature shown o...

Page 13: ...ble elimination Customer Service Make sure that the foil reception is snapped into place push it completely into the unit otherwise CS Do not pull out the form pot during the thermo forming process CS...

Page 14: ...r window soiled draught disturbs the sensor sensor defective Granules on sealings Sealings used Hole in the foil System pressure too low Display pressure loss Possible elimination Check wall socket ma...

Page 15: ...with rubber cap 188 530 can also be used as input pen 1 on off Magnet red or green red 110 890 to collect filling granules green 110 891 1 filling granules subsequent supply 110 852 1 3 kg supplied w...

Page 16: ...Erkodent Erich Kopp GmbH Siemensstra e 3 72285 Pfalzgrafenweiler Germany Tel 49 0 74 45 85 01 0 Fax 49 0 74 45 85 01 15 www erkodent com info erkodent com BA Erkopressmotion anl EN 04 04 2019...

Reviews: