9
to 4.
After thermoforming
the cooling time runs.
Afterwards further working
steps are indicated on the
display.
Pull form pot out of the
unit, in doing so the red
protection shield moves
upwards.
Take model and foil out of
the foil reception.
to 3.
10 °C before reaching
the rated temperature, a
signal sounds and a warn-
ing sign flashes. As soon
as the rating temperature is
reached, the thermoforming
process will be automati-
cally released.
Do not reach into the unit!
Risk of crushing!
Risk of
serious injuries
Notes:
The function field »X«
interrupts the respective
process.
Each termination has to be
confirmed.
If within 10 seconds the
next required working step
will not be performed, the
working program will be
switched off for safety
reasons.
to 2.
Place foil reception
with foil onto the insertion
ramp and push it thus far
under the heater that it
clicks into place.
The foil temperature
appears in the display,
the foil is heated.
The function field »X«
interrupts the heating
process and leads back
to the display
1.
If the foil is pulled out of
the heating area (max.
3 sec., otherwise the
heating process will be
stopped), the working steps
described under “
to
1.
“
appear again in the display.
When the rated
temperature is reached,
the heating switches off.
to 1.
Correct foil?,
if yes, confirm. In the
display further working
steps are indicated. The
visualisation disappears
with the next step.
If necessary, move support
for foil frame in the upper
position.
Put the selected foil in the
foil reception and clamp
with the foil securing ring.
Now or during the heating
process embed the model
in the granules.
Push form pot with model
backwards into the unit
until it clicks into place.
1.
Selected foil
2.
Foil will be heated
3.
Attention,
thermoforming process
4.
Cooling time
Thermoforming (
Pay attention to the notes
)
error 001:
blocked
support for foil
reception, see page 11