background image

5

a

b

c

d

e

1.

 Selected foil

to 1.

 Correct foil 

selected? 

If yes, confirm. 
As soon as the foil is 

confirmed the further 

working steps appear. 

These videos will be 

stopped with the next 

step.
Turn fixture for foil 

reception upwards 

and then to the right

(a/

!!

/

ok

until it clicks 

into place.
Put in the selected foil 

Erkodur 1.0 mm and 

clamp with the foil 

securing ring (

b)

.

2.

 Foil is heated

Embed the model now 

or during the heating 

process in the granules. 

(

c). 

Push form pot with 

model backwards into 

the appliance as far as 

it will go.(

d)

to 2.

  Place foil recep-

tion with plate onto 

the fixture and push it 

under the heating until 

it clicks into place(

e/f).

 

The foil temperature 

appears, the foil is 

heated.

3.

 Attention 

thermoform shortly

to 3.

 10 °C before 

reaching the rated 

temperature, a warning 

signal sounds and a 

warning sign flashes.

The functional field „X“ 

interrupts the heating 

process and leads back 

to the display (

1

).

If the foil is pulled out of 

the heating area (max 3 

sec.), the working steps 

videos reappear (1).

4.

 Rated temperature 

reached, 

thermoform!

to 4.

 After reaching the 

rated temperature the 

mandatory movement 

appears on the display 

to perform the thermo-

forming process.
Move by pivoting the 

foil reception at the grip 

cavity as far as it will 

go leftwards and push 

it downwards onto the 

form pot. 

The form pot has to be 

placed at the stop posi-

tion at the very back, 

otherwise the cylinder 

will not disengage. At 

the same time the pro-

tection shield (red) will 

be pulled downwards 

and disengage the 

cylinder 

(g).

Thermoforming

Upon reaching the rated 

temperature the heating 

switches off.

Summary of Contents for Erkopress 300 Tp

Page 1: ...element Sensor window Main switch Fixture for foil reception Mains connection on the side Pressure forming unit with integrated compressor and reserve compressed air Form pot with model plate and Gra...

Page 2: ...n the housing Only operate the machine under supervision Do not keep highly inflammable materials in direct area of the machine Usage as directed The Erkopress 300 Tp Tp ci unit should only be used wi...

Page 3: ...time favourites ok continue rated temperature new foil abort delete special functions add favourite heating off language selection change presettings heating on Sensor window Main switch Switch on app...

Page 4: ...nge of products that can be used with this machine and that have been available at the time of production of this unit 1 Select list of foils 3 Select 1 0 mm 2 Select Erkodur 4 selected foil Thumb lis...

Page 5: ...r having selected the desired foil from the list of foils the display 1 will be visible To save the foil as favourite select to favourites Recommendation If an Erkodent foil will be saved with the fac...

Page 6: ...3 Attention thermoform shortly to 3 10 C before reaching the rated temperature a warning signal sounds and a warning sign flashes The functional field X interrupts the heating process and leads back...

Page 7: ...ows the further steps to pull the model pot out of the unit and remove model and foil out of the foil reception g i 7 Display after thermoforming to 6 7 If the same foil is to be thermoformed choose t...

Page 8: ...ure and the cooling time have to be determined with the help of the special functions The new foils will be saved in the list of favourites and selected via this list Hint Max 240 C can be entered as...

Page 9: ...check with a blunt instrument If permanent impressions result generally the foil is ready for thermoforming d The heating switches off if the foil is pulled out of the heating area if heating off is s...

Page 10: ...the latter case as favourite The changes are done in the window selected foil or favourite see select foil or save favourite 1 Select change 2 Change rated temperature and cooling time 3 Thermoform o...

Page 11: ...ost position not enough pressure 300 Tp form pot is not in the rearmost position bent fixture of the foil reception transport damage system crash sensor window soiled granules on sealings hole in the...

Page 12: ...p 188 530 can also be used as input pen 1 on off magnet red or green red 110 890 to collect filling granules green 110 891 1 power supply cable 170 001 1 filling granules subsequent supply 110 852 1 3...