background image

Save favourites:

 

To save a foil in the list of favourites, this foil is selected out of the list of foils as described under 

“select foil“. New foils, either future Erkodent foils or foreign foils, are entered with the functional field 

»New foil« and are saved in the list of favourites.

 

After the desired foil is selected from the list of foils, the display shown at point 1. will be visible. 

1. Select add favourite 

Delete favourite:

2. Add favourite and confirm 

 

2. Select favourite

1. Select favourites 

4. Confirm delete 

 favourite

3. The favourite appears and 

  can be processed.

3. Select delete favourite

 

8

Summary of Contents for Erkopress 240

Page 1: ...t select language 7 Select foil 8 Save favourites 9 Thermoforming 10 Enter new foil 11 Delivery form available foil material Pressure forming unit with automated thermoforming process to connect to the existing compressed air system The Erkopress 240 unit is in accordance with the respective legal standards that are listed in the declaration of conformity on page 2 of this operating manual ...

Page 2: ...d personnel using original spare parts Otherwise the manufacturers liability and warranty expire Usage as directed The units are intended for the use in the dental thermoforming technique They must only be operated by instructed personnel and only using thermoforming material in Ø 240 mm and up to 2 0 mm thickness to adapt on suitable models Otherwise the product liability expires Installation ins...

Page 3: ... Bestimmungen in der jeweils aktuellen Version entspricht Richtlinie Maschinen 2006 42 EG EMV Richtlinie 2014 30 EU DIN EN 12100 Sicherheit von Maschinen EN 13849 1 Sicherheitsbezogene Teile von Steuerungen DIN EN ISO 14120 Sicherheit von Maschinen Trennende Schutzeinrichtungen Richtlinie 2011 65 EU gefährliche Stoffe RoHS EN complies with the following regulations guideline 2006 42 EC guideline 2...

Page 4: ... Attention leave at least 20 cm free space in the area of the fans Erkopress 240 Maintenance To ensure that the unit maintains its full function the rubber seals require replacing once a year when the unit is permanently in use The new sealing rings should be firmly pushed into position Sealing foil securing ring 179 025 Sealing cylinder 179 030 3 ...

Page 5: ...uring range up to 240 C foil dimensions Ø 240 mm thickness 0 2 0 mm operating pressure 4 5 bar factory setting required supply pressure 6 bar noise level 80 dB A Dimensions height 40 cm width 34 5 cm depth 59 cm weight 47 kg Electrics 220 240 100 110 120 Volt 50 60 Hertz max 1100 W Fuse 230 240 V 2 x T 5 A 100 115 V 1 x T 12 A H Heating medium wave infrared radiator 1000 Watt Erkopress 240 4 Mains...

Page 6: ...itioning models Counterpart to the groove on the form pot table Form pot with model disc 7 models 6 are placed on screws as shown and 1 in the middle To place up to 9 small models insert the model disc with the screws facing down Make sure that the distance between the models is at least 1 cm and do not exceed the ring The models must not extend beyond the marked ring The form pot must be placed o...

Page 7: ...unction fields on slight pressure For input the enclosed brush is equipped with a rubber cap However input is also possible with fingers Basic display Select language for any further use of the unit the language selected last time is used 1 Select language selection 2 Select language 3 Menu selected language Note The function field X inter rupts the respective process and has to be confirmed Note ...

Page 8: ...ith this machine Example Erkodur 0 8 mm 1 Select list of foils 3 Select 0 8 mm 2 Select Erkodur 4 Selected foil Functions of this display selected foil rated temperature cooling time change rated temp and cooling time save as favourite menu OK next step one step back 7 ...

Page 9: ...e entered with the functional field New foil and are saved in the list of favourites After the desired foil is selected from the list of foils the display shown at point 1 will be visible 1 Select add favourite Delete favourite 2 Add favourite and confirm 2 Select favourite 1 Select favourites 4 Confirm delete favourite 3 The favourite appears and can be processed 3 Select delete favourite 8 ...

Page 10: ...amp and push it thus far under the heater that it clicks into place to 5 Warning appears shortly before and dur ing cylinder release to 1 Correct foil if yes confirm In the display further working steps are indi cated The visualisation disappears with the next step Put the selected foil in the foil reception and clamp with the foil securing ring 1 Selected foil 2 Insert foil reception 5 Risk of cr...

Page 11: ...rated temperature 150 C cooling time 1 40 min After entering New foil the program guides you through the individual necessary entries The new foils can be saved in the list of favourites and selected via this list Note Max 240 C can be entered as rated temperature The cooling time has to be at least 30 sec Otherwise there might be malfunctions Select new foil 10 ...

Page 12: ...l Ø 240 mm Erkodur 240 0 5 mm Ø 240 mm clear 20 pieces 529505 Erkodur 240 0 6 mm Ø 240 mm clear 20 pieces 529506 Erkodur 240 0 8 mm Ø 240 mm clear 20 pieces 529508 Erkodur 240 1 0 mm Ø 240 mm clear 20 pieces 529510 Erkoflex bleach 240 1 0 mm Ø 240 mm transparent 20 pieces 589510 Erkoloc pro 240 1 0 mm Ø 240 mm transparent 20 pieces 599510 Erkoloc pro 240 1 3 mm Ø 240 mm transparent 20 pieces 59951...