Technical Description
4.6.3
1+1 Protection with XPIC (MMU2 F)
4.6.3.1
subrack Configurations
The protected 1+1 XPIC radio terminal configuration consists of four modems
MMU2 F 155 with XPIC capability, four RAUs, and two integrated dual-polarized
antennas or four separate antennas. See Figure 76 on page 98.
ML TN
MMU 2 F 155
MMU 2 F 155
MMU 2 F 155
MMU 2 F 155
ML TN
MMU 2 F 155
MMU 2 F 155
MMU 2 F 155
MMU 2 F 155
9966
Figure 76
1+1 XPIC configuration
The four modems MMU2 F 155 are housed in the AMM 6p C/D or the AMM
20p B, in four adjacent slots that share the same BPI-4 bus. See Figure 77
on page 99.
98
12/221 02-CSH 109 32/1-V1 Uen A 2008-03-14