Environmental Capabilities
•
ETS 300 019-1-4 class 4.1 NON-WEATHER PROTECTED
Location
•
Additional requirements for mast mounted equipment are included.
Note:
The temperature range is extended to +45
C.
This clause refers to the environment which an RBS for outdoor non-
weather protected location shall endure. The equipment must in all
situations fulfil legal requirements and not become hazardous to people.
The figures below refer to the environment that surrounds the cabinet
and the temperature is the shaded ambient air temperature.
Climatic conditions
The climatic conditions conform to
•
IEC 721-3-4 classes 4K2/4Z5/4Z7
•
ETS 300 019-1-4 class 4.1
In addition to this, Ericsson demands more rigorous values than stated
by IEC and ETSI above.
Table 78
Climatic conditions during outdoor operation
Environmental parameters
Value
Normal condition
Non-destructive
Temperature,
C
-33 - +45
-40 - +70
Relative humidity, %
15 - 100
15 - 100
Biological conditions
The biological conditions conform to
•
IEC 721-3-4 class /4B1/
•
ETS 300 019-1-4 class 4.1
Chemically active substances
The chemically active substances conform to
•
IEC 721-3-4 classes /4C2(4C1)/
•
ETS 300 019-1-4 class 4.1
Note:
The values of these capabilities are average yearly levels of
airborne contamination that can be accepted. It is assumed
that one of the contaminations is dominant at each site, and
that the others are present in insignificant amounts.
Mechanically active substances
The mechanically active substances conform to
•
IEC 721-3-4 class /4S2/
•
ETS 300 019-1-4 class 4.1
282 (306)
EN/LZT 123 2697
R5A
1998-08-13