Mobile Station Power Control
Description
The function is initiated when a CHANNEL_ACTIVATION message /
GSM:08.58:8.4.1/ containing MS Power is received from the BSC.
The value of the ordered MS power /GSM:08.58:9.3.13/ is passed
transparently to the MS.
RBS stores the MS power level received from BSC and includes it in
the L1 header of all downlink SACCH blocks /GSM:04.04:7.1/.
15.2.2
MS Power Control for an Active Channel
Supported channel numbers and Supported channel combinations /
GSM:05.02:6.4/, see the section above.
RBS actions:
•
Interpretation of the MS_POWER_CONTROL message
•
Storage of MS power level
•
Order MS to set the commanded power level
Description
The function is initiated when an MS_POWER_CONTROL message /
GSM:08.58:8.4.15/ containing MS Power is received from the BSC for
an active dedicated channel.
The value of the ordered MS Power /GSM:08.58:9.3.13/ is passed
transparently to the MS.
The MS Power parameters /GSM:08.58:9.3.31/ is not supported by the
RBS.
RBS stores the MS power level received from BSC and includes it in
the L1 header of all downlink SACCH blocks /GSM:04.04:7.1/. It
overwrites the MS power value set by any previous "Channel
Activation" or "MS Power Control" functions.
116 (306)
EN/LZT 123 2697
R5A
1998-08-13
© Ericsson Radio Systems AB
— All Rights Reserved —