INSTALLATION INSTRUCTION
Faktaansvarig - Subject responsible
6.5
Board IC-LU (ROF 157 5129)
Up to revision R2A
Note: Use only the cable (TSR BS 902 0001/__ or equivalent) for the wiring to the MDF.
External power input: This cable is used if the current of all Base Stations connected to the IC-LU exceeds 1.5A.
This cable connects either to another power supply in another cabinet or to the same cabinet’s power supply. The
current fed by this cable must also be considered in the power calculation of the BML 351 048.
Overvoltage Protection
All lines leading outside the building to Base Stations must be fitted with 90V gas-filled surge arresters between
every wire to ground.
Red
Speech
R
OF1575129/1
R1A
IC-SLU
BS2 9627
Express Power feeding to base stations
Red
Red
reset active
board not polled
board error
Red
Cell Link Unit
Red
Red
reset CLP
board not polled
External power input
V1
(+)
V0
(-)
via front connector
Serial communication to base stations
1
+
+
+
ON
1 2
Set switch 1 to ON to
disconnect 48V feeding
from the backplane and
enable feeding from front
(to enable set switch 1 to ON)
02
04
06
08
A C
SC0
SC0
SC1
To BS 4
10
12
14
16
SC0
SC0
02
04
06
08
A C
EPP (V0
(-)
)
To BS 1
To BS 2
to power supply
BML 351 013
RYS NB 101 20
RYS NB 101 22/3
RYS NB 101 19
connector for all lines.
EPP (V1
(+)
)
EPP (V0
(-)
)
EPP (V1
(+)
)
Processing
Unit
SC1
To BS 3
SC1
To BS 2
SC1
To BS 1
TSR BS 101 12/1500
The IC-LU board can supply up to
1.5A to the Base Stations via the
back plane. Higher currents have to
be supplied via the front connector.
board error and/or
Base Station not initialized