Ericsson AEGIS EDACS M-PA LBI-33056 Maintenance Manual Download Page 10

BATTERY PACKS

The battery pack connects to the bottom of the unit and

delivers a nominal 7.5 Volts dc to the radio. A recessed
on/off switch for the radio is located on the battery pack. An
internal fuse located in the radio’s Battery Plate protects the
radio and battery from excessive current draw. The battery
packs are available in several different capacities and sizes.

Radio contacts located on the top of the pack include

switched power, ground, the speaker enabling contacts and a
continuous power contact. In addition, four contacts are lo-
cated on the rear of the battery pack. These four contacts
provide connections to the slip-in type chargers or vehicular
chargers/repeaters while the battery pack is still connected
to the unit. The battery charging contacts are diode pro-
tected from external shorts.

The chargers utilize an internal thermistor in the battery

pack to sense temperature and automatically control charge
rate of the battery. This allows for a maximum charge rate
without overheating the battery pack. All battery packs can
be charged in less than 11/2 hours with the rapid type charg-
ers. Nominal full charge time in a standard charger is 14
hours. The Service Section contains a detailed outline and
schematic diagram of a typical battery pack. Further service
information for the battery packs is also presented in the
Service Section.

Chargers are available with nominal charge times of one

hour (rapid) and fourteen hours (standard). Combinations
include single (1) and multi (5 or 6) position, standard and
rapid charge units. In addition, the vehicular chargers/re-
peaters simultaneously charge the battery while the radio is
operating.

The battery packs should be fully charged in an appro-

priate charger before they are placed into service. This ap-
plies to new battery packs received from the factory and to
battery packs that have been stored for long periods of time.
A fully charged battery pack should have an open-terminal
voltage greater than 7.5 Volts. A battery pack in need of a
charge will cause the low battery "BAT" status flag on the
radio to turn on. This flag will turn on when the battery
pack’s voltage drops below approximately 6.8 Volts. The
low battery alert tone will also be heard when the battery
pack needs charging.

UNIVERSAL DEVICE CONNECTOR

The UDC is located on the side of radio just above the

PTT and Monitor Buttons. Various equipment such as the
audio accessories can be connected to the radio via the
UDC. The programming equipment is also connected to it
when the personality is programmed into the radio. The
UDC furnishes an excellent first-check-point for initial
bench checks without the need to disassemble the radio. Ta-
ble 2 lists all pins and their appropriate function. When the
radio is turned on it senses the resistance value between
UDC pins 9 and 1 and switches the appropriate circuits to
provide proper radio-to-accessory operation.

USABLE FREQ.

RANGE (MHz)

OPTION

NUMBER

PART NUMBER

TYPE

COLOR

BANDS

378 - 440

PANC1L

19A149061P10

Whip

Brown

378 - 440

PANC1U

19B234804P10

Helical

Black

440 - 470

PANC1F

19B234804P12

Helical

Red

440-514

PANC1N

19A149061P12

Whip

Orange

Table 1 - UHF Antennas

LBI-33056

10

Summary of Contents for AEGIS EDACS M-PA LBI-33056

Page 1: ...ance Manual AEGISTM EDACS M PATM UHF PORTABLE RADIO LBI 33056 TABLE OF CONTENTS Rear Cover Assembly LBI 38383 Front Cover Assembly Later LBI 38834 Control Board LBI 39157 Service Section LBI 33057 eri...

Page 2: ...authorized service technician or facility designated by the supplier Any repairs alterations or substitution of recommended parts made by the user to this equipment not approved by the manufacturer co...

Page 3: ...20 6 ounces with Extra High Cap Battery 952 grams 33 6 ounces TRANSMITTER High Low RF Power Output 3 Watts 1 Watt programmable on a per system or channel basis Maximum Frequency Separation 20 MHz no d...

Page 4: ...lling continuous in digital or private mode Data Rate 9600 baud Digital Private Mode Performance assured acquisition at 12 dB SINAD SINAD measured in clear mode Digital Private Mode Range equal to cle...

Page 5: ...n on System model to pro vide additional features not available on the Select model radio These radios can be programmed with up to fifty 50 systems with sixteen 16 groups in each or sixteen 16 system...

Page 6: ...gs located above and below the digits alert the operator to various radio conditions such as no control channel conventional mode enabled transmitter in operation and a low battery condition Scan and...

Page 7: ...lso provided at the UDC for an exter nal antenna or for test purposes This UDC antenna connection is also utilized for external antenna operation when the radio is locked in the vehicular charger or r...

Page 8: ...Figure 1 System Model Figure 3 Select Model Figure 2 Scan Model Figure 4 Side View All Models LBI 33056 8...

Page 9: ...HARGER CH6RA1 120 VAC 1HR CH6SA1 120 VAC 14HR CH6RA2 230 VAC 1HR CH6SA2 230 VAC 14HR UNIVERSAL DESK CHARGER CH1RA1 120 VAC 1 HR CH1SA1 120 VAC 14 HR CH1RA2 230 VAC 1 HR CH1SA2 230 VAC 14 HR Figure 5 O...

Page 10: ...ingle 1 and multi 5 or 6 position standard and rapid charge units In addition the vehicular chargers re peaters simultaneously charge the battery while the radio is operating The battery packs should...

Page 11: ...tems provide interface and connection between the PC and the radio when the personality is transferred from the PC into the radio PIN NAME INPUT OR OUTPUT USE 1 GROUND Case Ground 3 UDC RX AUDIO Outpu...

Page 12: ...des Class I Di vision 2 hazardous locations in the presence of Groups A B C and D atmospheres Hazardous locations are defined in the National Electri cal Code Useful standards NFPA 437A and NFPA 437M...

Page 13: ...educed Battery Packs Insure the battery packs are properly maintained Do not over or under charge them on a regular basis Verify the contacts are clean and free of corrosion Mechanical Since portable...

Page 14: ...Printed in U S A Ericsson Inc Private Radio Systems Mountain View Road Lynchburg Virginia 1 800 528 7711 Outside USA 804 528 7711 LBI 33056...