background image

OPERATION

Using The Desk Charger

1.

Plug in the charger and turn it on using the ON/OFF power switch lo-
cated in the rear.

2.

Turn the radio OFF and place it into the proper charging sleeve with
the speaker facing the front of the charger. If only charging a battery
pack, properly insert the battery pack into the charger as indicated on
the battery pack making sure the ON-OFF switch on the battery pack is
in the OFF position (M-RK battery packs do not have an ON/OFF
switch).

3.

STANDARD MULTI-UNIT CHARGER: The CHARGE (red) indicator
will light indicating the battery is being charged The proper charge cur-
rent for long or short case battery packs is selected by the insert micro
switch. To charge the battery to maximum capacity, let the battery pack
charge for at least 14 hours

4.

RAPID MULTI-UNIT CHARGER: The CHARGE (red) indicator will
light indicating the battery is being charged. (If the CHARGE indicator
is blinking slowly - the charger is in the pre-charging mode. The charger
should switch to normal charge within 10 minutes). When the READY
(green) indicator lights - charging is complete and the charger is in
trickle charge mode.

For indoor use only.  To reduce risk of injury, charge only nickel cad-
mium type rechargable batteries. Other types of batteries may explode
causing personal injury or damage.  Replace defective cords immedi-
ately.

CAUTION

14

Summary of Contents for 344A3072P1

Page 1: ...UNIVERSAL MULTI UNIT CHARGER STANDARD RAPID LBI 38706B Operator s Manual ericssonz TO PREVENT FIRE OR ELECTRIC SHOCK HAZ ARD DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE WARNING...

Page 2: ...the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV...

Page 3: ...uxiliary equipment not recommended or sold by the manu facturer To do so may result in a risk of fire electric shock or injury to persons 6 To reduce risk of damage to electric plug and cord pull by t...

Page 4: ...with damaged cord or plug replace them im mediately 10 Do not operate charger if it has received a sharp blow been dropped or otherwise damaged in any way return it to a qualified service shop 11 Do n...

Page 5: ...adapter illustrated in sketches B and C may be used to connect this plug to a two pole receptacle as shown in sketch B if a properly grounded outlet is not available The temporary adapter should be u...

Page 6: ...s Due to the temperature characteristics of nickel cadmium batteries the batteries will not accept a full charge at temperature extremes For maximum capacity recharge the battery pack at a room temper...

Page 7: ...watts FUSE RATING Rapid Charger F1 5 Amp 250 volt Standard Charger F1 315 mA 250 volt F2 600 mA 250 volt RECHARGE TIME Rapid Charger 1 hour Standard Charger 14 hours OPERATING TEMPERATURE RANGE 5 to...

Page 8: ...me i e two M RK and four M PD sleeve inserts in the same charger Both the Standard and Rapid Multi unit Chargers may be powered by either a 120 Vac 50 60 Hz or 230 Vac 50 60 Hz power source Power sour...

Page 9: ...i rectly to the wall due to the possible weight 26 lbs max involved We sug gest mounting the charger on an 18 x 18 plywood panel secured to the wall studs The following steps describe the process for...

Page 10: ...er keyhole mounting points Drill the holes to match the anchor s diameter and depth using a carbide drill Insert the anchor into the holes 2 Screw the four No 8 x 1 1 2 screws and mounting spacers pro...

Page 11: ...INDICATORS CHARGE RED CONTINUOUS Indicates battery is charging at the se lected charging rate STANDARD MULTI UNIT CHARGER 11...

Page 12: ...If both CHARGE and READY indicators are blinking fast immedi ately unplug the charger and return it for service If left in this con dition the battery may be severely overcharged causing personal inj...

Page 13: ...to continuous RED after the battery has an acceptable pre charge typically less than 10 minutes Cold or Hot Battery The CHARGE indicator stays in a blinking RED condition until the battery temperature...

Page 14: ...charged The proper charge cur rent for long or short case battery packs is selected by the insert micro switch To charge the battery to maximum capacity let the battery pack charge for at least 14 hou...

Page 15: ...attery pack excessively cooled by an environmental condition Defective Battery Battery pack with one or more of the internal cells shorted On occasion when charging a new battery or a battery which ha...

Page 16: ...ery or charger are dirty Clean with soft eraser 2 Pre charge too long RED LED blinks slowly for over 10 minutes Rapid charger only 1 Defective battery with shorted cells 3 Red charge LED ON for severa...

Page 17: ...072P6 The following pages illustrate and identify the accessories and replace ment parts available NOTE Complete chargers must be ordered using ap plicable package number 120 Vac Line Cord 344A3072P10...

Page 18: ...29 4R A9 0095 Rapid Charger Constant Current F29 4R A9 0092 Rapid Charger Power Supply F29 4R A9 0091 Rapid Charger Control Board F29 4R A9 0083 Standard Charger Control Board F29 4R A9 0096 Charger S...

Page 19: ...072P7 344A3072P10 120V M RK STANDARD 344A3072P9 344A3072P7 344A3072P10 230V M PA RAPID 344A3072P8 344A3072P5 344A3072P11 230V M PA STANDARD 344A3072P9 344A3072P5 344A3072P11 230V PCS RAPID 344A3072P8...

Page 20: ...NOTES...

Page 21: ...NOTES...

Page 22: ...NOTES...

Page 23: ...for the Equipment covered under Paragraph B 3 and only during the first three 3 months following the date of sale to the Buyer Thereafter labor will be charged at prevailing rates To be eligible for n...

Page 24: ...Ericsson Inc Private Radio Systems Mountain View Road Lynchburg Virginia 24502 1 800 528 7711 Printed in U S A...

Reviews: