SPECIFICATIONS*
OUTPUT VOLTAGE
Transmit and Receive Simultaneously
26.0 Vdc
±
1.0 Vdc @ 15 Amps (F801A)
13.0Vdc
±
0.5Vdc @ 3Amps (J801)
Receive only
Vdc @ 3 Amps (J801)
INPUT VOLTAGE
121 Vac
±
20% (60 Hz version)
230 Vac
±
15% (50 Hz version)
INPUT FREQUENCY
60 Hz
±
2 Hz (60 Hz version)
50 Hz
±
2 Hz (50 Hz version)
NOTE: For every + 1.0% change in the input frequency, the output voltage will not vary
more than + 1.6% from the output voltage measured at the nominal input line frequency.
INPUT LINE SURGE PROTECTION
150 V rated MOV (60 Hz version)
275 V rated MOV (50 Hz version)
DUTY CYCLE
For 0-18 Amp output
100% (Continuous Duty)
OUTPUT VOLTAGE RIPPLE
< mV p-p @ 25°C
< mV p-p @ -30°C
OUTPUT TRANSIENT RESPONSE
Overshoot
Not to exceed 30 Volts (F801A)
Undershoot
Not less than 22 Volts (F801A)
EFFICIENCY
70% @ rated TX/RX load current and nominal line voltage
FUSE CAPABILITY
Input
10 Amp (60 Hz version)
(2) 5 Amp (50 Hz version)
Output
5 Amp (Low Current Port)
20 Amp (High Current Port)
DIMENSIONS (HxWxD)
5.25" x 19" x 10.35"
WEIGHT
45 lbs.
OPERATING ENVIRONMENT
-30°C To + 60°C
* These specifications are intended primarily for the use of the service personnel.
LBI-38551
3
Summary of Contents for MASTR II 19A149979P1
Page 13: ...60 Hz POWER SUPPLY 19A149979P1 Rev A ASSEMBLY DIAGRAM LBI 38551 13...
Page 14: ...60 Hz POWER SUPPLY 19A149979 Rev A 289PS3 Sh 1 Rev C SCHEMATIC DIAGRAM LBI 38551 14...
Page 15: ...PARTS LIST LBI 38551 15...
Page 16: ...50 Hz POWER SUPPLY 19A149979P2 Rev A ASSEMBLY DIAGRAM LBI 38551 16...
Page 17: ...50 Hz POWER SUPPLY 19A149979P2 Rev A 289PS4 Sh 1 Rev C SCHEMATIC DIAGRAM LBI 38551 17...
Page 18: ...PARTS LIST LBI 38551 18...