BEA--220265-EN-04
B Page 19
CCD array camera OptoLine OL 80..
7.7.2 Configuring the 2nd measured value:
7.7.2.1 Setting the CAN address
➜
Call up the setup editor.
➜
Enter the camera device number in parameter 0.
1 for measured value 1 (right sensor)
➜
Enter the camera group number in parameter 1.
0 for measured value 1
➜
Enter the device
and
group number for the second measured
value in parameter 47 (sub address).
0.2 in parameter 47 for measured value 2 (left sensor)
➜
Enter a 1 in parameter 3 (reset), then change parameters to initi-
ate the reset.
7.7.2.2 Determining the operating mode
➜
Enter the device number for the second measured value in pa-
rameter 0.
2 for measured value 2
➜
Enter the group number for the second measured value in param-
eter 1.
0 for measured value 2
➜
Set the operating mode for the second measured value in param-
eter 6
"1" = contrasting edge
"2" = center between two contrasting edges
1 for measured value 2
➜
Enter the contrasting edge number by which measuring or guiding
is to be performed in parameter 7. The preceding sign indicates
the direction of counting:
The following applies for cameras mounted in the direction of
right
web travel:
No pre-sign - direction of counting from outside to inside.
Negative pre-sign - direction of counting from inside to outside.
The following applies for cameras mounted in the direction of
left
web travel:
No pre-sign - direction of counting from outside to inside.
Negative pre-sign - direction of counting from inside to outside.
1 for measured value 2
➜
Enter the second contrasting edge number in parameter 8 (only if
camera operating mode 2 is set).
No entry for measured value 2
7.7.2.3 Emergency guiding
➜
If necessary enter the sensor address that is to perform emergen-
cy guiding in parameter 9.
no entry for measured value 2
If the camera is only to output one measured value it is now