background image

888-83-018-00 rev. A • 05/ 06

4 of 6

Reconnect cables with 
terminal bolts and replace 
protective boots.

7

   

Replace battery cover, plugging the cord reel back in if unplugged, and tighten screws.

Verify proper 

polarity when 

attaching cables. 

Failure to do so will 

result in blown fuse 

on battery harness.

a

b

c

d

6

   

a

b

10mm

10mm

Connect Red (positive) lead before 
connecting Black (negative) lead. Be 
careful not to contact tools between 
terminals on battery and metal chassis.

1/8"

Summary of Contents for StyleView SV22

Page 1: ... down the standby button on the RUI for 1 3 seconds Power light will shut off d Remove front cover and disconnect RUI cables from jacks located on side of outlet box WARNING Only Ergotron specified batteries may be used in the StyleView Power System Please call customer care for details Do not replace the batteries while cart is located in an oxygen rich or hazardous environment Sparking may occur...

Page 2: ...y cover 10mm Unplug cord reel for better access 3 Remove protective boots terminal bolts and cables a b c d e f Remove Black negative lead before removing Red positive lead Be careful not to contact tools between terminals on battery and metal chassis 1 8 ...

Page 3: ...3 of 6 888 83 018 00 rev A 05 06 BATTERY MUST BERECYCLED LEAD 4 Remove old battery 5 Place new battery in tray and install new battery a b a b Old Battery New Battery ...

Page 4: ... the cord reel back in if unplugged and tighten screws Verify proper polarity when attaching cables Failure to do so will result in blown fuse on battery harness a b c d 6 a b 10mm 10mm Connect Red positive lead before connecting Black negative lead Be careful not to contact tools between terminals on battery and metal chassis 1 8 ...

Page 5: ...e a full charge and prolongs battery life NOTE Batteries may not achieve optimal performance until the 5th discharge recharge cycle Warranty on fully charged batteries left in an unused state for more than three 3 consecutive months is automatically void Warranty on fully discharged batteries left in an unused state for more than three 3 consecutive days is automatically void In order to avoid los...

Page 6: ... reservesthe right to make changesin the product design and or product documentation without notification to itsusers For the most current product information or to know if thisdocument isavailable in languagesother than those herein please contact Ergotron Customer Care at 800 888 8458 or consult the Ergotron Inc website at www ergotron com No part of this publication may be reproduced stored in ...