M6-20 Cap Screw

325-5272-00

 

Nylock Nuts

325-5186-00

1/2”Button-hd Screw

325-5193-00

48w Table

Shown without Control Box for easier view.

Side View

S t e p   5   -   I N S TA L L   C A B L E  T R AY

 

Align the Cable Tray with the back of the table so the holes on the threaded posts on the cross pan line up with 
the holes on the cable tray.  Attach the tray to the pan with three Nylock Nuts using your own 3/8" socket or the 
3-way wrench provided.  (The plastic end of the nut faces up.)

 

Connect a 1-meter Control Box Cable to each leg cable, then plug each into a port on the Control Box through 
the opening in the support pan.  Feed extra cable length through an opening in the support pan so it's organized 
in the Cable Tray.

Route the Keypad's cable back to the Cross Pan and plug it into the Control 

Box.  Feed extra cable length through an opening in the support pan so 
it's organized in the Cable Tray.

Plug the Power Cord into the Control Box.

Use the provided cable clips to route and organize cords.  Install one cable 

clip next to the Leg Gusset for the Keypad Cord.  Install the other clip next 
to the Cross Pan for the Control Box Cables.

S t e p   6   -   I N S TA L L   F E E T   A N D   H O M E  T H E   L E G S

Align one foot with each leg so the wheels are at the back.  Attach the foot 

to the leg with four M6x20 Socket-head Screws using the Anthro driver.  
Repeat for the other foot.

With the help of another person, carefully rotate the table onto its feet.  Plug 

in the table and use the keypad to move the table all the way down.  
Release the button and press it again to home the legs so they move in 
unison.

Add your equipment and route cords into the cable tray.  Carefully move the 

table through its entire range of motion to be sure that your power and 
data cables are long enough.  

CO N G R AT U L AT I O N S !    YO U R   E L E VAT E   I I   A S S E M B LY   I S   CO M P L E T E !

Summary of Contents for Elevate II

Page 1: ... 10 16 Product Part Elevate II 48w 29d MVBD48SS xx Elevate II 60w 29d MVBD60SS xx Built with Anthro DNA For the latest User Installation Guide please visit www ergotron com ASSEMBLY INSTRUCTIONS Elevate II Single Surface Table ...

Page 2: ...ent il est important de respecter certaines précautions de base notamment celles décrites ci dessous Lire intégralement les consignes avant d utiliser ce mobilier DANGER Pour limiter le risque de choc électrique toujours débrancher le mobilier avant de nettoyer AVERTISSEMENT Pour limiter les risques de brûlure d incendie de choc électrique ou de blessure aux personnes 1 Débrancher avant d installe...

Page 3: ...ew 31 325 5575 00 14 M6 10 Button head Screw 8 325 5503 00 15 M6x14 Flat head Screw 4 325 5435 00 16 3 4 Phillips SMS Zinc Screw 4 325 5370 00 17 1 2 Button hd Screw 3 325 5193 00 18 10 24 Nylock Nut 3 325 5186 00 19 M6 20 Cap Screw 8 325 5272 00 20 Control Box Cable not shown 2 400 5182 00 21 1 75 Phillips SMS Pan hd Screw 2 325 5772 00 not shown WELCOME Thank you for purchasing Anthro s Elevate ...

Page 4: ...face with six 3 4 Button Hd PB Screws 325 5575 00 using the Anthro driver STEP 2 INSTALL LEGS Align one Leg with one Leg Gusset so the cord feeds out of the Leg toward the center of the table The Leg will rest on top of the Gusset s button head screws so it may feel a little wobbly A Slide a Leg Housing over the Leg and down until it covers the Leg Motor and the six screw holes on the housing line...

Page 5: ...he keypad and its slider housing with the four pre drilled holes at the front of the keyboard surface so the buttons are face down at the front edge of the keyboard surface and the flat side of the housing is against the shelf The keypad can also be installed directly to the worksurface without the slider housing either so it extends in front of the table or so it s set back a bit Using four Phill...

Page 6: ...l Box Feed extra cable length through an opening in the support pan so it s organized in the Cable Tray Plug the Power Cord into the Control Box Use the provided cable clips to route and organize cords Install one cable clip next to the Leg Gusset for the Keypad Cord Install the other clip next to the Cross Pan for the Control Box Cables Step 6 INSTALL FEET AND HOME THE LEGS Align one foot with ea...

Page 7: ...table to its lowest position release the DOWN button then press and hold the DOWN button for 5 seconds The table will bump a few times then rest Raise the table to its highest position Watch all the cords and cables as the table moves to verify that cords aren t wrapped around anything and that nothing interferes with the movement of the table Every time you add equipment onto the table route cord...

Page 8: ...n rest Table won t move at all no up no down Has the table exceeded its duty cycle moving more than 6 minutes per hour or 2 minutes continuously If so rest the table for 20 minutes and try again Inspect the leg cables control box cable and power cable to be sure they are connected properly and not damaged Contact Anthro for replacements Test the cables Unplug the Leg Cable that is plugged into Por...