Operating instruction
Hydraulic system with Motor drive PXD compact
Document no.: B-00021
Edition 2019 09
Operating instruction EN
Copyright by Ergoswiss AG
9/25
The plastic housing PXD can be
snapped on the motor after wir-
ing the motor and mounting the
cable strain relief. Snap-fits in-
tegrated in the housing clasp
the cylinder of the motor.
3.2
Mounting and wiring of the control box
Mounting of the control box underneath a table top:
ATTENTION
During mounting of the control box the power cable must be disconnected from the mains!
1.
Place the control box to the desired location and mark the drill holes with a pen.
2.
Pre-drill two holes (Ø 3 mm).
Be careful not to drill through the table top!
3.
The control box is mounted with two screws (cap screws DIN7981C 4.8xL, cap-Ø 9.5 mm).
NOTE
The screws may be tightened with a maximum torque of 2 Nm!