Operating instruction
Hydraulic system with Motor drive PXD compact
Document no.: B-00021
Edition 2019 09
Operating instruction EN
Copyright by Ergoswiss AG
18/25
6
Synchronous operation of 2, 3 or 4 control boxes
6.1
Cable connections
By cascading multiple control boxes, multiple motor drives can be controlled simultaneously with just one
manual control switch. The control boxes can be connected using the PXD SYNC-2 cable (124.00088) or the
PXD SYNC-4 cable (124.00089).
PXD SYNC-2 cable
With the SYNC-2 cable two control boxes PXD compact can be
connected and synchronised.
→
The length of the SYNC-2 cable is 550 mm.
The SYNC cable cannot be extended. If necessary, the motor
cables can be extended!
NOTE
Always do reset before disconnecting!
Disconnect plug carefully -> risk of damage
PXD SYNC-4 cable
With the SYNC-4 cable 2, 3 or 4 control boxes PXD compact
can be connected and synchronised.
→
The length of SYNC-
4 cable is 1’800 mm
→
Two connected SYNC-
4 cables have a length of 2’000
mm
Each control box needs one SYNC-4 cable.
The SYNC cable cannot be extended. If necessary, the motor
cables can be extended!
The SYNC-4 cables of each control box are to be connected.
→
The loose ends do not have to be connected. Howev-
er, connecting the loose ends will not have any influ-
ence to the system.