 Purpose 

Stellar/170 is a mobile stand-aid lifter/hoist, designed to transfer persons in institutions such as 

nursing homes, hospitals, care centres and in homecare. Stellar  can be used for transfer 

between bed and chair/wheelchair, from chair to another chair and from wheelchair to a 

toilet/commode. 

 

Stellar is approved to transfer with a maximum load on 170 kg. (375 Ib). 

The use of the Stellar requires the following instructions: 

 

 

Personnel have received qualified instruction by Winncare Nordic in using the Stellar. 

 

The Stellar has been assembled correctly and according to this user instruction. 

 

NEVER use the Stellar for other purposes than described in this user instruction. 

 

Ensure the user cannot be squeezed or restricted in the lifting situation. 

 

The Stellar has been developed for use with Winncare Nordic lifting slings and other sling 

products authorized by Winncare Nordic. See Winncare Nordic’s user instruction for 

slings for specific information about which models that can be used. 

 

The Stellar is intended for indoor use under normal temperatures (+2°C to +40°C) or (36°F 

- 104°F) and relative humidity (40-90%). 

1.2

 

Safety instructions 

 

Important – Warning!

 

This user instruction must be read thoroughly before the Stellar is taken into use

.

 

 

All parts must be mounted correctly according to this user instruction. 

 

There must be no indication of wear and tear on the Stellar or the lifting sling. 

 

NEVER begin lifting if there is suspicion of any defect (abnormal sound, loose brackets 

etc.). In such cases it is important to find the cause and to take the Stellar out of service 

and your dealer or Winncare Nordic contacted. 

 

The lifting capacity must never be exceeded. When using the Stellar in connection with 

other components e.g. slings it is always the component with the LOWEST weight 

capacity that decides the maximum lifting capacity. 

 

Ensure that neither carers/helpers nor patients/users can be hurt during the lifting. 

 

Using the Stellar may not run on uneven surfaces or threshold. 

 

Never lift higher than necessary in the actual lifting situation. 

 

See section 5.1 (annual check) for further information.  

 

Note!

 If the footplate is not mounted, it may cause the Stellar to tilt. 

 

 

Summary of Contents for Stellar/170

Page 1: ...n Important information This user instruction must be read before the Stellar 170 is used This user instruction is intended for technicians installers therapists and other personnel in connection with...

Page 2: ...2...

Page 3: ...Charging 11 2 5 Transport 12 3 Use 12 3 1 Using the Stellar 12 3 2 Using the control box 12 3 3 Adjusting the knee support 13 3 4 Using the slings 13 4 Maintenance 15 4 1 Cleaning 15 4 2 Storage 15 4...

Page 4: ...s that can be used The Stellar is intended for indoor use under normal temperatures 2 C to 40 C or 36 F 104 F and relative humidity 40 90 1 2 Safety instructions Important Warning This user instructio...

Page 5: ...is heard from the Stellar the lifter must not be used before personnel authorised by Winncare Nordic have carried out a safety check on the unit 4 Check the lifting slings for any damages especially a...

Page 6: ...of repair or annual check Content of the box 1 Base for legs spreading 2 Mast and lifting arm 3 Actuator 4 Hand control with battery 5 Control box 6 Handles 7 Knee support 8 Tools Allen key spanner 9...

Page 7: ...Assembly the handles on the mast with two screws and tighten with the Allen key Fig 1 6F Fig 1 6F 6 The hand control lifting arm and electrical leg spreader are connected to the control box Fig 1 6G S...

Page 8: ...ngs are attached incorrectly it is always the onus of the carer helper to ensure that the sling is correct for the situation needs and is correctly fitted Hygienically the hook can be opened closed wi...

Page 9: ...Connecting plug electrical leg spreading 4 Connecting plug power supply 5 ON indicates that main supply is on 6 Charge indicates charging on the battery see section 2 4 7 Lift up down The up down func...

Page 10: ...eading Press and the leg spreading moves together Press and the leg spreading will spread outwards 2 3 Safety functions Emergency stop This function is only to be used in an emergency e g if the Stell...

Page 11: ...here are 3 symbols on the hand control which indicate the power level in the battery Battery 25 An audible battery alarm will alert when there is a 25 capacity remaining in the battery Battery 50 Reco...

Page 12: ...ation a readout tool is required This service data tool can be purchased from Winncare Nordic or your local dealer 017 00202 Service data tool Read out box with cables More information about the servi...

Page 13: ...ull the click lock 2 out and set the angle to the user when the user stands up Release the click lock and ensure that the mechanism is locked Note As additional support the calf belt 3 can be tightene...

Page 14: ...ble Ensure that the patient feels no discomfort Ask the user to press their feet down onto the plate and to stretch both knee and hip joints The carer may help by placing a hand on to the knee and pre...

Page 15: ...CHECK AND TROUBLESHOOTING 5 1 Annual check The manufacturer Winncare Nordic stipulates that a qualified and authorised person MUST check this hoist at least once a year This annual check is also reco...

Page 16: ...ol Solution Try using another hand control Alternative is to get a new hand control from the dealer Possible cause Flat battery Solution Charge battery see section 2 4 Fault Some functions work while...

Page 17: ...y cycle 10 max 2 min 18 min Manually emergency lowering Yes Electronically lowering Yes Electrical details Power supply Input 100 240 VAC 50 60 Hz max 0 4 A Output voltage 24V Control box Output 250 V...

Page 18: ...ist from wall to CSP at min height legs spread 220 mm g Max reach at 600 mm reference height 40 mm h Max reach from base 390 mm i Reach from base with legs spread to 700 mm 220 mm j Base height 120 mm...

Page 19: ...nvironment if not handled in an environmentally responsible way 7 2 Battery The Stellar is equipped with one battery which may be returned either to a local recycling station or to Winncare Nordic at...

Page 20: ...ACCESSORIES Wall charger 017 00200EU 017 00200AUS 017 00200UK Wall charger EU plug Wall charger AUS plug Wall charger UK plug Spare parts list can be ordered Contact Winncare Nordic for more informat...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...one 45 70 27 37 20 Fax 45 70 27 37 19 Email Info winncare dk www winncare dk Manufacturer Winncare Nordic ApS Taarnborgvej 12 C 4220 Korsoer Denmark 9 3 4 2 E F C L A S S I E N I S O 1 0 5 3 5 910 007...

Reviews: