2.6 Transport

 

The Pallas stand-aid lifter is most safely transported using the original packing. 

Symbols are printed on the packaging to ensure the best information to carrier companies

 

3 USE

 

3.1 Using Pallas 175

 

Pallas 175 is ready for use if all the assembly instructions have been followed.

 

3.2 Tips for using slings

 

Lifting from sitting position: 

Place the sling behind the patient by pushing the 

back support all the way down to the small of the 

back.

 

 

 

Close the safety belt – over the waist, approx. at the 

navel and tighten it. The safety belt should sit tightly 

above the waist. 

 

Brake the wheel chair and move the hoist/lift to the 

user. Lift the user’s feet onto the foot plate; bring 

the hoist/lift forwards until the knee support is very 

close to the users’ knees.

 

 

 

Summary of Contents for Pallas/175

Page 1: ...user instruction must be read before the Pallas 175 is used This user manual is intended for technicians therapists and other personnel in connection with the use and maintenance of the Pallas 175 lif...

Page 2: ...2...

Page 3: ...functions 11 2 5 Charging 12 2 6 Transport 13 3 Use 3 1 Using Pallas 175 13 3 2 Tips for using slings 13 3 3 Seated transfer 16 3 4 The use of accessories 16 4 Maintenance 4 1 Cleaning 17 4 2 Storage...

Page 4: ...y instructions Important Warning Read the user manual and these safety instructions thoroughly before using Ensure that all parts are mounted correctly according to this user manual The maximum liftin...

Page 5: ...ther defects If there is any sign of a defect the Pallas 175 must be taken out of service 5 If any abnormal sound is heard from Pallas 175 the lifter must not be used before personnel authorised by Wi...

Page 6: ...Mast and lifting arm Hand control Charger Actuator Control box Spreader bar User instructions 1 6 Mounting instruction Following step by step the assembling guidance of the Pallas 175 1 Place the cha...

Page 7: ...red emergency button on the electrical box before connecting motor and box 5 Connect the cable from the lifting actuator which has a 2 pin plug to the underside of the electrical box 6 Connect the co...

Page 8: ...he correct use of slings Hanging slings on the Winncare Nordic spreader bar Winncare Nordic accepts no responsibility if slings are placed incorrectly it is always the onus of the carer helper to ensu...

Page 9: ...rol box 2 2 Pictograms and functions Hand control 1 Hand control basic Fig 2 2 The hand control has functions for up down Emergency lowering button Lifting actuator Plugs for charger and hand control...

Page 10: ...should be protected against sudden changes in temperature humidity Adjusting the lifter Directional guide Can be used for controlling the forward and backward direction during transportation Foot peda...

Page 11: ...on lowers the patient It can be used if hand control is out of order This function is only available if the emergency button is not activated Emergency stop This function is only to be used in an emer...

Page 12: ...hat require regular charging Winncare Nordic recommends that the Pallas 175 is charged when it is not in use or every night Pallas 175 is fitted with a diode which gives the following information conc...

Page 13: ...een followed 3 2 Tips for using slings Lifting from sitting position Place the sling behind the patient by pushing the back support all the way down to the small of the back Close the safety belt over...

Page 14: ...ossible and look forwards Ask the user to press down onto the plate and to stretch both knee and hip joints The carer may help by placing a hand on to the knee and press the knee lightly downwards Con...

Page 15: ...ing leg support forward on the outer side of the thighs Then place them under the thighs and cross the sling straps in front The user may be raised in a more or less reclining position e g a relativel...

Page 16: ...ort in place to help guide the client It can also be an advantage to have the client s feet on the footplate to assist the transfer 3 4 The use of accessories T grip Locking pin is loosened from below...

Page 17: ...d with detergent or disinfectant 4 2 Storage Pallas 175 must be stored in a dry environment with relative humidity under 90 If the Pallas 175 is not to be used over a longer period of time it is best...

Page 18: ...f the buyer to ensure that this annual check is carried out If it is necessary to replace any parts due to wear or damage these must be obtained purchased from Winncare Nordic 5 2 Troubleshooting Faul...

Page 19: ...sible cause Defect battery Solution Replace battery Possible cause Connection between the charger and the hand control are defect Solution Try using another hand control Alternative is to get a new ha...

Page 20: ...Electrical details Power supply Input Power supply Output Output voltage Control box Output Battery capacity Internal charger output Internal charger max current IP class Charger Hand control Noise No...

Page 21: ...min height legs spread d Maxi reach at 600 mm reference height e Maxi reach from base f Reach from base with legs spread to 700 mm k Maxi height of CSP l Min height of CSP m Hoisting range p Maxi int...

Page 22: ...ions that contain halogens aluminium lead acid batteries ABS plastic steel may damage the environment if not handled in an environmentally responsible way 7 2 Battery Pallas 175 is equipped with 2x12V...

Page 23: ...s not separated from the ground and the chassis The product should be reused where possible Refer to user instruction Safe working load User sling 8 ACCESSORIES Accessories Item number Description 017...

Page 24: ...one 45 70 27 37 20 Fax 45 70 27 37 19 Email info Winncare dk www Winncare com Manufacturer Winncare Nordic Ltd Taarnborgvej 12 C 4220 Korsoer Denmark 9 3 4 2 E F C L A S S I E N I S O 1 0 5 3 5 910 00...

Reviews: