D1 Series
User Guide, Rev. 03 (September 2016)
Serial port and reset timer setting
Automati Reset Timer
allows to re-initalise the
entre radiomodem if, for any reason, the output data
stops. The tme interval before the complete unit reset
may be of
15 seionds, 30 seionds, 1, 2, 4, 8 and 16
minutes
Reset tme
S1 Dip 1
S1 Dip 2
S1 Dip 3
Timer OFF
OFF
OFF
OFF
15 sec
ON
OFF
OFF
30 sec
OFF
ON
OFF
1 min
ON
ON
OFF
2 min
OFF
OFF
ON
4 min
ON
OFF
ON
8 min
OFF
ON
ON
16 min
ON
ON
ON
Serial port setni
S1 Dip 4
RS232
OFF
RS485
ON
Software configuration
Download from ERE WIRELESS web site (
www.erewireless.com
) the latest version of configuration software
(confSW_D1).
The configuration must be done through a RS232 interface
System Requirements
Operative System: Windows 98 SE, Windows ME, Windows2000, Windows XP, Windows Vista, Windows 7,
Windows 8, Windows 10.
Minimum screen resolution: 800 x 600 dpi.
Preliminary Operations:
1) Install the Configuration Software on your computer.
2) Connect the serial port of RMO 400 to the computer communication port with a
NO Null Modem
cable
and open the configuration utility.
3)
In Options Menu
select the appropriate computer
Communication Port
and the
Operative Band
of D1.
Care attention to select the Operative Band in according to the model of the available radiomodem.
4) Link
together
pin n° 1
and
pin n° 2
, respectively CONFIG and DC SUPPLY, of the 3-poles supply connector
(JP3).
5) Connect, with the proper polarity, a stabilized supply then turn on to enter in Configuration Mode.
6) Use
TAB
key and
Up, Down, Left
and
Right Arrows
to move into the displayed fields.
7) A function may be activated choosing the relative box.
8) To leave the configuration process exit the program, disconnect the communication cable, turn off supply
and disconnect pin n°1 from pin n°2 of the supply connector.
9) For normal operation connect the supply source between pin n°2 (positive) and pin n° 3 (negative) of the
3-poles supply connector (JP3)
12