Dct_427_02
Figure 15 : Internal electric scheme of opto-coupled inputs
The minimum command voltage for the detection is:
3.5 V
The maximum command voltage is:
35 V
3.9.1.1
Inputs functioning
This function can also be controlled with AT commands:
AT+GPIOGET
This command is used to read the inputs. The reading is done with the following format:
AT+GPIOGET=<n>
with:
<n>
= 7 : reading input 1
8 : reading input 2
9 : reading input 3
Examples:
Command
Response
Interpretation
AT+GPIOGET=7
+GPIOGET: 7= 0
OK
Input 1 read at 0, command voltage > 3.5V on
input 1
AT+GPIOGET=9
+GPIOGET: 9= 1
OK
Input 3 read at 1, the input 3 is connected to
GND