EG_GenPro53e_1040_UG_003_UK
Page 26 / 71
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCO&GENER reserves the right to make any modifications
- Connect the GSM antenna to the FAKRA-D connector.
- For the connection to the DTE, connect the V24 link via the 9-pin Sub D cable.
- Connect the supply cable to the continuous and regulated power source (for an automobile
application, see the paragraph 5.2).
- Connect the supply cable to the modem and turn on the external power supply.
The modem is now ready.
There are 4 different displays depending on the application installed inside the equipment:
- Without application: corresponds to Boot_Loader.
- Standard library.
- The application ERCO & GENER
EasePro_Vx
.
- The owner application.
5.1.3 Checking the communication with the modem
5.1.3.1 Without Application
The
GenPro 53e
does not contain any application; it will return the menu of the Boot-Loader.
Connect the link RS232 between the DTE (the COM port) and the modem (DCE).
Set the RS232 port of the DTE as follows:
▪
Bits per second: 115 200 bps,
▪
Data bits: 8,
▪
Parity: None,
▪
Stop bits: 1,
▪
Flow control: material.
Use a communication software like HyperTerminal ® of Windows.
Menu by default when there is no
application inside the equipment (example of display)
Bootloader V2.39 GL53 UA GenLoc53e ENF (HW16 rev B/C)
GSM voltage = 4347 mV
1 - Update application
2 - Erase objects
M - GSM direct access
A - Advanced
P - Power off
E - Exit
In the case where no communication can be established with the modem:
▪
Check the RS232 connection between the DTE and the modem (DCE),
▪
Check the configuration of the COM port of the DTE.