background image

18V CHARGER 

     ERB607CHR

Light 

ON/OFF 

flash

Status

Red  on            

Defective  Battery

Red flash        

 -  -  -  -  -

Battery Temperature 

Protection

The temperature of battery 

pack is less than 0

o

C or 

more than 45

o

C.

Green  on        

Fully Charged

Green 

flash    

- -  -  -  -  - Charging

BATTERY TEMPERATURE PROTECTION

This charger has a battery temperature protection 

feature. When the charger detects a battery pack 

that is too hot or cold (the light will be red and flash), 

it automatically activates the protection circuit, 

and suspends charging until the battery pack has 

reached the correct temperature. The charging 

process will then automatically begin (the light will 

be green and flash). This feature ensures maximum 

battery life.

 

Note: 

please make sure every half year recharger 

battery pack one time if the battery pack stock long 

time.

At this time charging directly charger red light could 

be lighting, please remove battery pack from charger 

and standing it for a period time before recharge.

LEAVING THE BATTERY PACK IN THE CHARGER

If a fully charged battery pack is left in the charger, 

the Light will remain green. The battery pack will 

remain charging with a maintenance trickle current.

DEFECTIVE BATTERY PACKS

This charger will detect a defective battery pack. 

When a defective battery pack is inserted into the 

charger, the charger will try to repair it. This process 

will last about 30mins (the light will be green and 

flash). If the repair is successful, the charger will 

Summary of Contents for ERB607CHR

Page 1: ...18V CHARGER ERB607CHR ERB607CHR...

Page 2: ...Original Instructions Version 2 0...

Page 3: ...the goods This guarantee does not affect your statutory rights This guarantee is only valid in the UK For further technical advice spare parts or repair service outside of guarantee please con tact th...

Page 4: ...hildren without supervision If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard When the charger is in use...

Page 5: ...place 15 When charging batteries ensure that the battery charger is in a well ventilated area and away from inflammable materials Batteries can get hot during charging Do not overcharge any batteries...

Page 6: ...ns and follow them to the letter This will help to prevent risks and hazards 1 Always be alert when using this product so that you can recognise and handle risks early Fast intervention can prevent se...

Page 7: ...f 3 15A Positive terminal Negative terminal Double insulation Waste electrical products must not be disposed of with household waste Please recycle where facilities exist Check with your local authori...

Page 8: ...3 1 2 1 BATTERY PACK 2 CHARGER 3 CHARGE INDICATOR LIGHT Not all the accessories illustrated or described are included in standard delivery...

Page 9: ...ltage 100 240V 50 60Hz Output voltage 14 4 20V Charging current 3A Rated Input power 78W Charge battery Li ion Protection class II Machine weight 0 45kg Battery pack ERI606BAT ERI660BAT Charging Time...

Page 10: ...er charging approx 1 2 hours the light will stay green without flashing which means the battery is full and charging is completed WARNING When battery charge runs out after continuous use or exposure...

Page 11: ...ill be green and flash This feature ensures maximum battery life Note please make sure every half year recharger battery pack one time if the battery pack stock long time At this time charging directl...

Page 12: ...ger or immerse charger in water or any other liquid 4 When the battery pack fails to produce sufficient power on jobs that were previously done easily please recharge your battery do not continue to u...

Page 13: ...duct a If the battery pack is only partly discharged it may be re charged in less than rated charging time b If the battery pack and ambient temperature are very cold hot it may take longer to re char...

Page 14: ...this appliance may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured blue must be connected to the terminal which is marked...

Page 15: ...30 EU Restrictions of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment 2011 65 EU Waste Electrical and Electronic Equipment WEEE 2012 19 EU Standards and technical specif...

Page 16: ......

Reviews: