6 kg SDS-MAX ROTARY HAMMER

 

d. Remove any adjusting key or wrench before turning the power tool 

on. 

A wrench or a key left attached to a rotating part of the power tool may result 

in personal injury.

 

e. Do not overreach. Keep proper footing and balance at all times. 

This 

enables better control of the power tool in unexpected situations.

 

f. Dress properly. Do not wear loose clothing or jewellery. Keep your 

hair, clothing and gloves away from moving parts. 

Loose clothes, jewel-

lery or long hair can be caught in moving parts.

 

g. If devices are provided for the connection of dust extraction and col-

lection facilities, ensure these are connected and properly used. 

Use of 

these devices can reduce dust related hazards.

4.   Power tool use and care

 

a. Do not force the power tool. Use the correct power tool for your ap-

plication. 

The correct power tool will do the job better and safer at the rate for 

which it was designed.

 

b. Do not use the power tool if the switch does not turn it on and off. 

Any power tool that cannot be controlled with the switch is dangerous and must 
be repaired.

 

c. Disconnect the plug from the power source before making any ad-

justments, changing accessories, or storing power tools. 

Such preven-

tive safety measures reduce the risk of starting the power tool accidentally.

 

d. Store idle power tools out of the reach of children and do not allow 

persons unfamiliar with the power tool or these instructions to operate 

the power tool. 

Power tools are dangerous in the hands of untrained users.

 

e. Maintain power tools. Check for misalignment or binding of moving 

parts, breakage of parts and any other condition that may affect the 

power tools operation. If damaged, have the power tool repaired be-

fore use. 

Many accidents are caused by poorly maintained power tools.

 

f.  Keep  cutting  tools  sharp  and  clean. 

Properly  maintained  cutting  tools 

with sharp cutting edges are less likely to bind and are easier to control. 

 

g.  Use  the  power  tool,  accessories  and  tool  bits  etc.,  in  accordance 

with these instructions and in the manner intended for the particular 

type of power tool, taking into account the working conditions and the 

work  to  be  performed. 

Use of the power tool for operations different from 

intended could result in a hazardous situation.

5.   Service

 

a. Have your power tool serviced by a qualified repair person using only 

Safety Instructions identical replacement parts. 

This will ensure that the 

safety of the power tool is maintained.

HEALTH ADVICE

WARNING!

 When drilling, sanding, sawing or grinding, dust particles will be 

produced.  In  some  instances,  depending  on  the  materials  you  are  working 

with, this dust can be particularly harmful to you (e.g. lead from old gloss paint).
You are advised to consider the risks associated with the materials you are working 

Summary of Contents for ERB121SDS

Page 1: ...ERB121SDS 6kg SDS MAX ROTARY HAMMER...

Page 2: ......

Page 3: ...is product carries a guarantee of 24 months If your product develops a fault within this period you should in the first instance contact the retailer where the item was purchased This guarantee specif...

Page 4: ...un plugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock e When operating a power tool outdoors use an extensi...

Page 5: ...d Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of...

Page 6: ...or hidden electric cable gas and electric pipe before you start any drilling task 13 Chisel bits and drill bits may be flung out of the machine accidentally and cause serious injury 14 Before starting...

Page 7: ...lls Double insulation The tool is double insulated This means that all the external metal parts are electri cally insulated from the mains power supply This is done by placing insulation bar riers bet...

Page 8: ...the switch and the performance of the machine 6 1 SDS MAX CHUCK PROTECTION RING 2 LOCKING SLEEVE 3 DEPTH GAUGE LOCKING SCREW 4 DEPTH GAUGE 5 VENTILATION SLOTS 6 OPERATION MODE SELECTOR SWITCH 7 ON OF...

Page 9: ...er level LwA 106 dB A Uncertainty KwA 3 dB A Wear hearing protection Dust from material such as paint containing lead some wood species minerals and metal may be harmful Contact with or inhalation of...

Page 10: ...ation emission value may also be used in a preliminary assessment of exposure Calculating the actual period of use can be difficult and the HSE website has a spread sheet to help calculate exposures f...

Page 11: ...re operation at low tempera tures is unavoidable use appropriate clothing and gloves to keep warm and dry Plan your work schedule to spread any high vibration tool use across a number of days Health S...

Page 12: ...ssories Be fore undertaking any maintenance or operations on the rotary hammer isolate the plug from the power supply 1 AUXILIARY HANDLE See Fig 1 2 3 Adjust the position of the auxiliary handle by tu...

Page 13: ...little and repeat step 3 until the bit locks firmly into place 4 FITTING SDS MAX CHISELS See Fig 7 8 These are inserted in the same way as drill bits Once the bit is locked in place the bit can be ro...

Page 14: ...igh Power Mode position 8 should only be used for chiselling concrete or when using break through bit Selecting the speed frequency and impact energy Rotate the regulator 8 to choose a position approp...

Page 15: ...il it is locked 9 HAMMER DRILLING ACTION See Fig 13 Use good quality SDS Max drill bits Select the Hammer drilling position on the operation mode selector Apply moderate pressure during operation ap p...

Page 16: ...the machine does not work before the 8 hour warning period is over and the warning Red light emitting diode 10 keeps blinking this probably indicates the motor is damaged If there is no light indicato...

Page 17: ...ngerous to the user and people in the vicinity and professional help should be sought for its removal and disposal 15 OVERLOAD CLUTCH The overload clutch will actuate when a certain torque level is re...

Page 18: ...ough This will prevent the drill from jamming When drilling a large hole first drill a pilot hole using a smaller drill bit Always apply pressure to your drill bit in a straight line and if possible a...

Page 19: ...ord is damaged it must be re placed by a special cord or assembly available from the manufacturer or its service agent TROUBLESHOOTING If your rotary hammer will not operate check the power at the mai...

Page 20: ...l lows the instruction below IMPORTANT The wire in the mains lead are coloured in ac cordance with the following code Blue Neutral Brown Live The wire that is coloured blue must be connect ed to the t...

Page 21: ...l health and safety requirements of the following directives 98 37 EC Machinery directive 2004 108 EC Directive EMC 2006 95 EC Low voltage equipment Standards and technical specifications referred to...

Page 22: ...20...

Page 23: ...6kg SDS MAX ROTARY HAMMER...

Page 24: ...177879...

Reviews: