INSTALLATION

ELECTRICAL

UNPACKING

PREPARATION

Upon receipt, immediately inspect the carton for damage during transit. Signs of rough handling

may indicate internal damage in the air cleaner. Carefully unpack the unit and examine it for

concealed shipping damage. If the unit is damaged, contact the carrier to file a claim.

Carefully read the entire manual before starting installation. Authorities having jurisdiction should

be consulted prior to installation. Permits may be required. If there are no local codes, installation

should conform to the National Electrical Code. The electrical supply, volts, amps, hertz, and

phase, must correspond to that on the unit rating plate. Refer to dimensional drawings for the inlet

and supply dimensions for the duct connections, electrical inlets, and unit clearances before

setting the unit in place. The supply side duct opening at the discharge end of the unit is small

and operates at high velocity. A gradual transition to the larger supply duct should be used and

extra care taken to prevent the accidental dislodging of internal duct insulation in the transition.

Take note of the side clearance required to access blower motor and drive belts, and the space

required to replace the filters. Recommended minimum side clearance is 25" on the door side

and 12" on the power side.

The Series 3000 can be wired for 230 or 460 line voltage. Typical running amps at 230 volts

range from 8.3 to 13 amps depending on the filter configuration and external static load. The

schematic below illustrates the wiring required for each line voltage. The control box will

accommodate conduit from 1/2" to 1 1/4" in each of two bottom knockouts. Field wire the unit with

wire suitable for a 30 amp service and a full load of 13 amps.

BLUE

BLUE

BLUE

240V 3PH

460V 3PH

TERMINAL BLOCK

LINE

LINE

JUMPER

JUMPER

BLUE

GROUND LUG

GROUND

CHASSIS GRND

TERMINAL BLOCK

BLUE

BLUE

BLUE

BLUE

BLUE

YELLOW

YELLOW

BLUE

BLUE

BLUE

BLUE

BLUE

BLUE

TI

TI

T2

T2

T3

T3

T4

T4

T5

T5

T6

T6

T9

T9

T7

T7

T8

T8

24V RELAY SOCKET

460V 3PH 1-SPEED MOTOR

240V 3PH 1-SPEED MOTOR

240/460 V /24V

TRANSFORMER

YELLOW

YELLOW

RED

RED

BROWN

BROWN

BROWN

BLACK

BLACK

CONTROLLER

BLUE

1

7

8

9

2

A

B

3

4

5

6

H1

H1

H2

H2

H3

H3

H4

H4

Summary of Contents for Dust Free 3000 Series

Page 1: ...oyse City TX 75189 0519 1 972 635 9565 Series 3000 This manual is copyright protected by ERAMCO Any reproduction of this manual in part or full without the written permission of ERAMCO constitutes a violation of the U S copyright laws and is subject to prosecution Printed in the U S by the Graphics Productions Department of ERAMCO 1998 Air Cleaners ...

Page 2: ...ided along the right side of the unit for servicing the filters motor or blower The unit comes standard with a 5 HP motor with 7 5 HP motor available as an option Other options include vertical air discharge Inlet Outlet plenums roof mounting I beams and insulated weather tight cabinets A wide assortment of filter options are also available Refer to the replacement parts list at the end of this ow...

Page 3: ...he equipment Call the factory if the distributor dealer is not available UNIT LOCATION 3 Multi Unit Configuration Dual Unit Configuration Single Unit Configuration Top view of room Top view of room Top view of room Place unit no less than 12 feet from wall Place unit no less than 12 feet from wall Place unit no less than 12 feet from wall No less than 25 of room length No less than 25 of room leng...

Page 4: ...and extra care taken to prevent the accidental dislodging of internal duct insulation in the transition Take note of the side clearance required to access blower motor and drive belts and the space required to replace the filters Recommended minimum side clearance is 25 on the door side and 12 on the power side The Series 3000 can be wired for 230 or 460 line voltage Typical running amps at 230 vo...

Page 5: ...utside of the joint to cover the gasket and to assist in developing an air and water tight joint ASSEMBLY Verify that the electrical service is the correct voltage current capacity and phase as listed on the unit nameplate Refer to the wiring diagram and verify that the motor and the control transformer are wired correctly Install an electrical disconnect to ensure safe servicing of the unit and e...

Page 6: ...g collar To replace the collar push it against the inner race of the bearing turn the collar in the direction of the shaft rotation until tight then tighten the set screws Tightening the locking collar in the direction of the fan rotation will result in further tightening of the collar should the set screw work loose FAN WHEEL ADJUSTMENT If the fan is not centered in the scroll and or is rubbing a...

Page 7: ...ree 3 inches away from the bottom to allow operation of the bottom door latches If 4 x4 timers are used be sure that they are both long enough to support the weight and oriented so as to transfer the weight of the unit to the underlying support structure If attachment to the support structure is required the floor or back side may be field drilled for bolts or screws Seal all penetrations with sil...

Page 8: ...ir leaks Place bolts or screws where they will not interfere with filter insertion or removal Take care to locate the duct work so that the filter and motor are easily serviced Locate and shim the support beams or pads so they equally support the load PAD MOUNT The unit should be supported on beams or pads that are high enough that water cannot rise to the bottom of the unit and damage the filters...

Page 9: ...lm must be removed prior to operation Remove the filter cabinet door and slide out the adsorbent filter tray Remove the screws that hold the end panel in place and remove the end panel Slide the individual adsorbent filters from the tray remove the protective wrap and place the filters back into the adsorbent filter tray Replace the end panel and the screws Repeat the process for the remaining fil...

Page 10: ... 95 Ashrae short pocket V bag Set of 2 used with sorbent panels 98 D O P LW bank Set of 2 Refillable sorbent media panel empty 1 120 lbs bulk Charcoal for refill 150 lbs bulk Permanganate for refill 5 HP blower motor 7 5 HP blower motor Drive belt 95 D O P mini pleat Set of 2 99 97 D O P Hepa Set of 2 5 w g Magnahelic gauge 50 ft tubing for Magnahelic gauge Ozone generator grid plate 1 24V remote ...

Reviews: