INSTALLATION
ELECTRICAL
UNPACKING
PREPARATION
Upon receipt, immediately inspect the carton for damage during transit. Signs of rough handling
may indicate internal damage in the air cleaner. Carefully unpack the unit and examine it for
concealed shipping damage. If the unit is damaged, contact the carrier to file a claim.
Carefully read the entire manual before starting installation. Authorities having jurisdiction should
be consulted prior to installation. Permits may be required. If there are no local codes, installation
should conform to the National Electrical Code. The electrical supply, volts, amps, hertz, and
phase, must correspond to that on the unit rating plate. Refer to dimensional drawings for the inlet
and supply dimensions for the duct connections, electrical inlets, and unit clearances before
setting the unit in place. The supply side duct opening at the discharge end of the unit is small
and operates at high velocity. A gradual transition to the larger supply duct should be used and
extra care taken to prevent the accidental dislodging of internal duct insulation in the transition.
Take note of the side clearance required to access blower motor and drive belts, and the space
required to replace the filters. Recommended minimum side clearance is 25" on the door side
and 12" on the power side.
The Series 3000 can be wired for 230 or 460 line voltage. Typical running amps at 230 volts
range from 8.3 to 13 amps depending on the filter configuration and external static load. The
schematic below illustrates the wiring required for each line voltage. The control box will
accommodate conduit from 1/2" to 1 1/4" in each of two bottom knockouts. Field wire the unit with
wire suitable for a 30 amp service and a full load of 13 amps.
BLUE
BLUE
BLUE
240V 3PH
460V 3PH
TERMINAL BLOCK
LINE
LINE
JUMPER
JUMPER
BLUE
GROUND LUG
GROUND
CHASSIS GRND
TERMINAL BLOCK
BLUE
BLUE
BLUE
BLUE
BLUE
YELLOW
YELLOW
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
TI
TI
T2
T2
T3
T3
T4
T4
T5
T5
T6
T6
T9
T9
T7
T7
T8
T8
24V RELAY SOCKET
460V 3PH 1-SPEED MOTOR
240V 3PH 1-SPEED MOTOR
240/460 V /24V
TRANSFORMER
YELLOW
YELLOW
RED
RED
BROWN
BROWN
BROWN
BLACK
BLACK
CONTROLLER
BLUE
1
7
8
9
2
A
B
3
4
5
6
H1
H1
H2
H2
H3
H3
H4
H4