background image

1050.00

HANDLE HEIGHT

 

22.00 

 36.00 

 72.00 

 92.00 

 17.00 

 

20.00 

 

20.00 

 

20.00 

 136.00 

45.00
Backset

B

BOTTOM OF DOOR

 155.00 

 214.00 

16.00

MIN

 1634.10 

 20.20 

 77.50 

 680.00 

 715.00 

A

A

 65.00 

 47.00 

 47.00 

 126.00 

SECTION A-A

SPINDLE DATUM

 2.50 

2.20

THIS HOLE IS ON INTERNAL SIDE ONLY.

DEPTH OF 10mm

2.20 

THIS HOLE IS ON 
INTERNAL SIDE ONLY.

 129.50 

 40.00 

PREPARATION DETAIL

13.00

Not to scale. All dimensions are in mm and are nominal. ERA 
reserves the right to change specification without notice. It is the 
responsibility of the door manufacturer to ensure that the finished
product meets any required safety and performance specification.  

Summary of Contents for TOUCHKEY

Page 1: ...TOUCHKEY AUTO FIRE LOCK INSTALLATION GUIDE ...

Page 2: ...SPINDLE DATUM 2 50 2 20 THIS HOLE IS ON INTERNAL SIDE ONLY DEPTH OF 10mm 2 20 THIS HOLE IS ON INTERNAL SIDE ONLY 129 50 40 00 PREPARATION DETAIL 13 00 Not to scale All dimensions are in mm and are nominal ERA reserves the right to change specification without notice It is the responsibility of the door manufacturer to ensure that the finished product meets any required safety and performance speci...

Page 3: ...k into the prepared door and fasten with appropriate screws 2 Set latches to left or right handed by pulling the latch outwards and twisting to the correct position 3 a Turn the thumbturn check all hooks and the centre deadbolt retract b Return the cylinder to the normal position c Press the trigger on the centre gearbox to fire the hooks and centre deadbolt Please separate installation instructio...

Page 4: ...s refer to 2b d Look for any sign off resistance during operation which may indicate the fitting is not correct Composite keeps are adjustable 2mm horizontally and vertically timber keeps are adjustable 2mm horizontally A Centre Line Position the keep and fasten to the frame with the appropriate screws for the substrate being used Once keeps are fitted open and close the door to check it is workin...

Page 5: ...allation checks Check the functions of the lock as above Make sure that the keeps are in the nominal position with full adjustment if required Close door and activate the lock The hooks should fall into the keeps Make sure the deadbolt works with the cylinder Undo the deadbolt and retract the hooks and latches to open the door Post installation checks 1 2 3 1 2 3 4 5 AUTO FIRE MPL ...

Page 6: ... of the frame Open the door depress the steel trigger between the latch and deadbolt in the centre gearbox both top and bottom hooks and centre deadbolt will be thrown into the locked position To retract the deadbolt and hooks rotate the thumbturn cylinder away from the lock jamb If the lock operates with the door open but has a stiff key operation with the door closed this may indicate that the c...

Page 7: ...porarily disable the hooks To do this please use a piece of tape placed over the hooks aperture on the face bar to hold them into the retracted position It is also important that compression of the gaskets is achieved on the latches only The hooks and deadbolt are security measures and should operate in fresh air With the hooks disabled please close the door until it latches Check that the leaf is...

Page 8: ...be twisting the cylinder Refit the handle taking care not to twist the cylinder Lock drive bars cannot operate in router groove Remove lock from door and check independently Locate the cause of resistance and rectify by removing material Stiff key operation Door not latched correctly Relieve pressure on latches by gently pushing or pulling the door closed Too much compression on hinges Adjust hing...