Operating instructions

DMX mode:

Operating in a DMX control mode environment gives the user the greatest flexibility when it comes  
to customising or creating a show. In this mode you will be able to control each individual trait of  
the fixture and each fixture independently. 

Press the 

“FUNCTION”

 button to display 

‘The DMX device address set:’

, you can now adjust the DMX 

address from 1 to 511 by using the        and       buttons. 
You can then connect the DMX controller, the display will show  

‘DMX-512 Add.:’

 

‘PMP:  F:’

.  

The PMP (haze output) and F (fan speed) can be adjusted via the DMX controller.

DMX channel mode:

Electronic Fluid-level-sensor:

If the fluid runs out whilst the unit is in operation the unit will continue to operate for approx. 2 minutes, 
after this time the Electronic Fluid-level-sensor will stop the unit working to protect it. When this happens 
the LCD display will flash and show 

‘Beware: No Liquid!’

, this means the machine has run out of fluid, 

please refill.  
When this happens please do the following:

Power off the unit and disconnect from mains power supply.
Refill the fluid tank. (See page 4 for instructions on fluid replenishment)
Reconnect the mains power supply.
The unit can now be operated again. 

Troubleshooting:

When the LCD display flashes and shows 

‘Machine Temperature is too HIGH’

.

This could indicate the air filter on the side of the unit needs maintaining, please see page 7 for further 
instructions. Alternatively this could indicate that the PCB is faulty. If the problem persists, please  
contact your dealer.
When the LCD display flashes and shows 

‘Temperature sensor error’

.

This could indicate that the heater is faulty and is not heating up or the heater isn’t getting up to the 
right temperature. Please power the unit off and then back on. If the problem persists, please contact 
your dealer.

Channel

Value

LCD display will show

Function

CH1

000-255

PMP (0-100%)

Haze output volume (0-100%)

CH2

000-255

F (0-100%)

Fan speed (slow-fast)

Summary of Contents for Stage Haze 1500

Page 1: ...Order code EQLED357 Stage Haze 1500 User Manual...

Page 2: ...ING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Ne...

Page 3: ...6 push button menu with LCD display PowerCON input 3 Pin XLR input output 5 Pin XLR input output Stage Haze 1500 265mm 575mm 423mm POWER INPUT 240V 50Hz FUSE F8A 250V HAZE OUTLET EXTREMELY HOT DO NOT...

Page 4: ...t into the metal collar on the fluid cap making sure it clicks securely into position Installation Install the unit in a well ventilated area Use in an insufficiently ventilated room can lead to the c...

Page 5: ...now adjust the fan volume from 0 to 100 by using the and buttons Once set you can then use the timer button to enable this mode The display will show Haze wait ___S Haze start ___S with the settings...

Page 6: ...the LCD display will flash and show Beware No Liquid this means the machine has run out of fluid please refill When this happens please do the following Power off the unit and disconnect from mains po...

Page 7: ...will periodically have to remove the side cover of the flightcase and remove the air filter to clean it After cleaning please make sure to dry the air filter thoroughly before installing it back into...

Page 8: ...MX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensu...

Page 9: ...5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin...

Page 10: ...ssible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material...

Page 11: ...www prolight co uk Stage Haze 1500 User Manual 11...

Page 12: ...www prolight co uk Stage Haze 1500 User Manual 12...

Reviews: