Equinox EX-2500
Operations
EC-3 Operations:
For normal strobe operation:
Make sure all three switches and indicators are
OFF,
you can now adjust the
“INTENSITY”
and
“FLASH SPEED”
controls to your desired setting. The strobe will now function as normal, the
speed can be adjusted from 1 to 25 flashes per second.
For use as a blinder:
Blinder mode 1:
Press the
“BLINDER”
button and the
“WINK”
button, you can now adjust the intensity and
the blinder rate (timer). The blinder will now wink
ON
and
OFF
at regular intervals set by the
“BLINDER RATE” control.
Blinder mode 2:
If you press the
“BLINDER”
button but not the
“WINK”
button, the strobe will now fade down
during the blinder operation.
You can also use the
“CYCLE”
button in both blinder modes. With the
“CYCLE”
button pressed
when you press the
“BLINDER”
button it will only activate the blinder once for each time you
press the
“BLINDER”
button.
The “BLINDER RATE” button adjusts the length of time the blinder is illuminated from 0.2 to a
maximum of 1 second.