Equinox ESP-2 OPTO Serial Hub Installation and User Guide
3.6 Serial Port Attributes
Each serial port has a set of attributes, which may be modified.
NOTE:
When a port is configured for the serial redirection connection method, the attributes are
specified within the protocol. Therefore, although you may change the attributes, any changes
you specify will not take effect.
Table 12 lists the serial port attributes with their valid and default values.
Inactivity time-
out
Specifies the length of time before the configuration utility is disconnected if
there is no activity. Valid values are 0-65535 seconds.
For example, a value of 60 indicates the configuration utility will be
disconnected if there is no activity for a period of 60 seconds.
A 0 value disables the inactivity time-out. The default value is 0 (disabled).
Table 12: Serial Port Valid and Default Values
Attribute
Valid and Default Values
Baud rate
Valid values: 50, 75, 110, 134, 150, 200, 300, 600, 1200, 2400, 4800,
9600, 19200, 38400, 57600, 76800, 115200 and 230400
Default value: 19200
Bits per character
(size)
Valid values: 5, 6, 7 and 8
Default value: 8
Parity
Valid values: None, Even, Odd, Mark and Space
Default value: None
Stop bits
Valid values: 1 and 2
Default value: 1
Flow control
Valid values: None and XON/XOFF
Default value: None
Flow control settings are full duplex
Table 11: Configuration Utility Connection Method Configurable Items (Continued)
Item
Description