background image

www.prolight.co.uk

Dragonfly Quad

  

User Manual

11

WEEE notice

Correct Disposal of this Product 
(Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries  
with separate collection systems)

This marking shown on the product or its literature, indicates that it should not be disposed of 
with other household wastes at the end of its working life. To prevent possible harm to the  
environment or human health from uncontrolled waste disposal, please separate this from other 
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.

Household users should contact either the retailer where they purchased this product, or their 
local government office, for details of where and how they can take this item for environmentally 
safe recycling.

Business users should contact their supplier and check the terms and conditions of the  
purchase contract. This product should not be mixed with other commercial wastes for disposal.

Summary of Contents for EQLED101

Page 1: ...Order code EQLED101 Dragonfly Quad User Manual V1 4 ...

Page 2: ...r gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 100 240V 50 60Hz Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically If the equipment is dropped or da...

Page 3: ...ates amazing lighting shows when used in multiples but also makes an outstanding centrepiece 8 x 12W quad colour LEDs Beam angle 4 5 Pixel mapping capabilities DMX channels 11 or 37 selectable Auto sound active and master slave modes plus built in programs 0 100 dimming and variable strobe Pan 630 Tilt 360 continuous rotation Quick release omega clamp included 4 push button menu with LCD display I...

Page 4: ...8 Handles 09 IEC power input 10 Fuse F5A 250V 11 IEC power output 12 Power switch 13 Microphone 14 3 Pin XLR DMX input 15 3 Pin XLR DMX output DRAGONFLY QUAD DMX SLAVE SOUND MASTER MENU ENTER DOWN UP 01 03 02 04 07 05 06 08 08 POWER IN POWER OUT ON OFF MIC DMX IN DMX OUT www prolight co uk 11 10 09 02 14 15 13 12 08 08 In the box 1 x fixture 1 x omega clamp 1 x power cable 1 x user manual ...

Page 5: ...ng To exit out of any of the above options press the MENU button 11 channel mode Channel Value Function CH1 000 255 Pan Movement 0 630 CH2 000 127 Tilt 1 Movement 0 360 128 191 Fast slow continuous reverse rotation 192 255 Slow fast continuous rotation CH3 000 127 Tilt 2 Movement 0 360 128 191 Fast slow continuous reverse rotation 192 255 Slow fast continuous rotation CH4 000 255 Master dimmer 0 1...

Page 6: ...ovement 0 360 128 191 Fast slow continuous reverse rotation 192 255 Slow fast continuous rotation CH3 000 127 Tilt 2 Movement 0 360 128 191 Fast slow continuous reverse rotation 192 255 Slow fast continuous rotation CH4 000 255 Master dimmer 0 100 CH5 000 009 No function 010 255 Strobe slow fast CH6 000 255 LED 1 Red 0 100 dimming CH7 000 255 LED 1 Green 0 100 dimming CH8 000 255 LED 1 Blue 0 100 ...

Page 7: ...ss the sound active mode press the MENU button on the front of the unit to show Pati Mode on the LCD display Now press the ENTER button and use the UP and DOWN buttons to choose between the following PanTilt Angle 1 Tilt movement angle 210 ideal for fixtures situated on the ground PanTilt Angle 2 Tilt movement angle 90 ideal for fixtures mounted on the ceiling or similar PanTilt Angle 3 Tilt movem...

Page 8: ...use the UP and DOWN buttons to choose YES or NO Press the ENTER button to confirm the setting this will reset all settings to factory defaults To exit out of any of the above options press the MENU button Fixture position reset To reset the fixtures positions press the MENU button on the front of the unit to show System reset on the LCD display Now press the ENTER button to perform the reset To ex...

Page 9: ...s from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using ...

Page 10: ...cables Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing Grounding the shield could cause a short circuit and erratic behaviour Special note Line termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Using a cable terminator will decrease the ...

Page 11: ...ossible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentall...

Page 12: ...www prolight co uk Dragonfly Quad User Manual 12 ...

Reviews: