background image

www.prolight.co.uk

Colour Raider Uplighter Pack

  

User Manual

6

Operating instructions

DMX mode:

Operating in a DMX control mode environment gives the user the greatest flexibility when it comes  
to customising or creating a show. In this mode you will be able to control each individual trait of  
the fixture and each fixture independently. 
To access the DMX mode, press the 

“MENU”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to show  

Addr

 on the LED display. Now press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to 

choose one of the 2/3/4/4 or 8 DMX channel modes.  
Press the 

“ENTER”

 button to confirm the setting. The display will now show  

d001

 on the LED display. 

Press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to set the required DMX address.  

Press the 

“ENTER”

 button to confirm the setting.

  

To exit out of any of the above options, press the 

“MENU”

 button.

2 channel mode:

Channel Value

Function

CH1

000-009 No function

010-019 Red

020-029 Green
030-039 Blue
040-049 White
050-059 Yellow
060-069 Magenta

070-079 Cyan

080-089 Dark Orange
090-099 Lime Green

100-109 Salmon Pink
110-119 Turquoise

120-129 Mint Green
130-139 Amber

140-149 Purple
150-159 Light Blue
160-169 Dark Blue
170-255 Light Pink

CH2

000-009 No function

010-069 Colour fade (speed slow-fast)
070-129 Colour change (speed slow-fast)
130-189 Colour fade sound active  

(sensitivity low-high)

190-255 Colour change sound active  

(sensitivity low-high)

3 channel mode:

Channel Value

Function

CH1

000-255 Red dimmer (0-100%)

CH2

000-255 Green dimmer (0-100%)

CH3

000-255 Blue dimmer (0-100%)

4-1 channel mode:

Channel Value

Function

CH1

000-255 Red dimmer (0-100%)

CH2

000-255 Green dimmer (0-100%)

CH3

000-255 Blue dimmer (0-100%)

CH4

000-255 White dimmer (0-100%)

Summary of Contents for Colour Raider Uplighter Pack

Page 1: ...Order code EQLED038 Colour Raider Uplighter Pack User Manual...

Page 2: ...off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipme...

Page 3: ...m angle 25 683 Lux 2m full on DMX channels 3 4 4 or 8 selectable Static colour colour change colour fade auto run sound active and master slave modes M10 rigging point for clamp 0 100 dimming and vari...

Page 4: ...ions 01 LED display 02 Function buttons 03 Microphone 04 3 Pin DMX input 05 3 Pin DMX output 06 IEC power input 07 IEC power output 08 Fuse T3A 250V 09 Carry handle 10 M10 rigging point 07 10 09 05 04...

Page 5: ...A I L H o L d b L A C A u t o S 0 1 S 1 7 S t t Static colour mode A u 1 A u 2 A u t o Auto modes S o 1 S o 2 S o u n Sound modes S P 1 S P 9 S P E E Speed setting d I 1 d I 9 d I N N Master dimmer S...

Page 6: ...ss the ENTER button to confirm the setting To exit out of any of the above options press the MENU button 2 channel mode Channel Value Function CH1 000 009 No function 010 019 Red 020 029 Green 030 039...

Page 7: ...e speed slow fast 070 129 Colour change speed slow fast 130 189 Colour fade sound active sensitivity low high 190 255 Colour change sound active sensitivity low high 4 channel mode Channel Value Funct...

Page 8: ...ENTER button and use the UP and DOWN buttons to choose one of the sound modes between So 1 So 2 Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU bu...

Page 9: ...he DMX fail setting press the MENU button and use the UP and DOWN buttons to show FAIL on the LED display Now press the ENTER button and use the UP and DOWN buttons to select between Auto auto mode bL...

Page 10: ...ollowed by the and buttons to adjust the sound sensitivity 07 Activates the DMX mode Please note the DMX address and channel must be preset in the menu 08 Activates the static colour manual modes use...

Page 11: ...lowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data...

Page 12: ...e a cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen...

Page 13: ...can be connected is 12 fixtures 3 packs 240V or 4 fixtures 1 pack 120V including the first fixture After the maximum number of fixtures are connected a new power run will need to be started Please no...

Page 14: ...vent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of ma...

Page 15: ...www prolight co uk Colour Raider Uplighter Pack User Manual 15...

Page 16: ...www prolight co uk Colour Raider Uplighter Pack User Manual 16...

Reviews: