background image

www.prolight.co.uk

Arcus 2000 Low Fogger

 

User Manual

4

In the box:  

1 x fixture, 1 x 2.5m output hose, 1 x output nozzle,  

2 x jubilee clips, 1 x powerCON cable & 1 x user manual

Product overview & technical specifications

FOG FLUID

DO NOT OPERATE 

WITHOUT EQUINOX FLUID

CLOSE

WATER

EMPTY W

ATER T

ANK

BEFORE TRAN

SPORTA

TION

OPEN

LOW WATER

INDICATOR

MAX. WATER

INDICATOR

REMOTE CONTROL

INPUT

DMX INPUT

DMX OUTPUT

WARNING! DO NOT BLOCK AIR INLET!

WATER DRAIN

POWER

SWITCH

ON

OFF

ON

OFF

DRAINAGE

SWITCH

POWER INPUT:

220-240V~50/60Hz

FUSE:

F10A 250V

01

19

21

20

21

02

06

07

03

04

18

17

15

16

14

05

12

11

13

09

08

10

01 - Function buttons
02 - LCD display
03 - Low water indicator
04 - Max. water indicator
05 - 5-Pin DMX input
06 - 5-Pin DMX output
07 - Remote control input
08 - PowerCON input
09 - Fuse F10A 250V
10 - Power on/off switch
11 - Drainage on/off switch

12 - Water drainage  

    

 

pipe

13 - Carry handle
14 - Fog output
15 - Water tank lid
16 - Water tank handle
17 - Air intake
18 - Fluid bottle
19 - Output nozzle
20 - 2.5m output hose
21 - Jubilee clip

Summary of Contents for Arcus 2000

Page 1: ...Order code EQLED390 Arcus 2000 Low Fogger User Manual...

Page 2: ...THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never...

Page 3: ...250V Dimensions 400 x 345 x 795mm Weight 23kg Order code EQLED390 The Arcus low fog machine produces a thick low lying cloud without the need for dry ice that hugs the floor and dissipates without ri...

Page 4: ...ARNING DO NOT BLOCK AIR INLET WATER DRAIN POWER SWITCH ON OFF ON OFF DRAINAGE SWITCH POWER INPUT 220 240V 50 60Hz FUSE F10A 250V 01 19 21 20 21 02 06 07 03 04 18 17 15 16 14 05 12 11 13 09 08 10 01 Fu...

Page 5: ...ate blue when heated Low Water Level If the unit is powered on without water runs out of water mid use the pump will shut off the display will flash Warning Low water Level and the red low water indic...

Page 6: ...powered back on the green max water indicator will illuminate If the red indicator is still illuminated this indicates there still isn t sufficient water in the tank Repeat the steps above to top up t...

Page 7: ...ATERIALS or FLAMMABLE FLUIDS Installation Install the unit in a well ventilated area Use in an insufficiently ventilated room can lead to the condensation of the fog fluid The resulting slippery surfa...

Page 8: ...MENU STOP Manual mode Press the button on the unit to display FOG VOLUME ___ FAN SPEED ___ Press the button to switch between FOG VOLUME and FAN SPEED you can now adjust the fog volume from 0 to 100 a...

Page 9: ...frequent cleaning of the unit Make sure the machine has cooled before cleaning Please use a soft lint free and moistened cloth Never use alcohol or solvents Clean the output nozzle after each use to...

Page 10: ...ng all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data tran...

Page 11: ...cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin...

Page 12: ...possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of materi...

Reviews: