background image

6

Problem

Possible Cause

Repair Procedure

2b. Blower inoperative.

2b. Check for 115 vac at the blower motor
terminals. Check motor resistance: 10 ohms
maximum.

2c. Thermostats open.

2c. Check for continuity, at room temperature.

2d. Thermal fuse open.

2d. Check for continuity.

2e. Heating elements.

2e. Check resistance: 25 ohms maximum open.

2f. Dryer timer.

2f. Test for 115 vac between either terminal of
88° C thermostat & either terminal of 110° C
thermostat.

3. Clothes hot
and damp at the
end of the dry
cycle.

3a. Blocked filter.

3a. Remove, clean, and replace filter.

3b. *No cold water supply.

3b. Cold water reuired for dryer to function
properly.

3c. * Machine not leveled.

3c. Condenser water flow disturbed. Level unit
and retest.

3d. Blower impeller.

3d. Remove and clean. Also check to see if
condensing channel is clogged with lint.

3e. * Condenser water valve
inoperative.

3e. Test for 110 vac across the valve terminals.
If present, valve may be defective.

3f. * Blower housing to Tub Seals
mismatched.

3f. Disassemble blower housing from tub.
Ensure that seals are positioned properly &
reassemble.

4. Long drying
time.

4a. High suds detergent.

4a. Use Equator detergent, or other low-suds
brand.

Excessive detergent.

Measure detergent, using 2 tablespoons or 1/8
cup maximum.

4b. Hot and cold water hoses
reversed.

4b. Connect hoses to the proper inlet valves.

4c. Dryer section malfunction.

4c. See #2 and #3 above for tests to perform.

5. Clothes stiff
and wrinkled.

5a. Overdrying.

5a. Set dryer timer for a shorter cycle

5b. High suds detergent.

5b. Use Equator detergent, or other low-suds
brand.

5c. Excessive detergent.

5c. Measure detergent, using 1 tablespoon.*

* Applies only to models EZ 3600 C and EZ 2500 C

Summary of Contents for CLOTHES PROCESSOR EZ 3600 C

Page 1: ...EQUATOR Advanced Appliances SERVICE MANUAL SPARE PARTS CATALOG AND First Edition October 2003 COMBINATION WASHER DRYER MODELS EZ 1500 EZ 2500 C EZ 3600 C CEE www WasherDryer com...

Page 2: ...6 INSTALLATION 2 WASH CYCLE 2 5 DRY CYCLE 5 6 SPARE PARTS CATALOG 7 18 CABINET 7 9 OSCILLATING GROUP 10 12 CONTROLS 13 14 WATER INLET 15 16 VENTILATION 17 18 TESTING THE ELECTRONIC CONTROL MODULE 19 T...

Page 3: ...under warranty and does not constitute warranty work Installation e g improper hook up or leveling Maintenance e g cleaning of air and or water filter Damage e g Replacing broken door handle Most work...

Page 4: ...pair Procedure 1 Won t fill 1a No power input 1a Check that the cord is plugged in and circuit breaker or fuse is OK Test unit power switch 1b No water pressure 1b Check that fill hoses are connected...

Page 5: ...ontrol Module See Testing the Electronic Control Module If correct replace the Control If test on terminals 1 to 7 fail replace timer If tests on terminal 8 9 12 through 15 fail replace motor 2c Motor...

Page 6: ...7 fail replace timer If tests on terminals 8 9 or 12 15 fail replace motor 7d Motor tachometer 7d Check tachometer resistance See Testing the Drive Motor 8 Timer doesn t advance 8a Water supply off 8a...

Page 7: ...power input 1a Check that cord is plugged in and circuit breaker or if fuse is OK Test unit power switch 1b Door not closed 1b Close door firmly so that it latches tightly 1c Door switch 1c Close the...

Page 8: ...3d Remove and clean Also check to see if condensing channel is clogged with lint 3e Condenser water valve inoperative 3e Test for 110 vac across the valve terminals If present valve may be defective 3...

Page 9: ...1 level for CEE 36 112901939 Adhesive hook 10 113200152 Clamp 39 112400459 Module housing 11 113800478 Shock absorber long 40 13800459 Spring 12 114300725 Outlet hose elbow 42 112300233 Door ring hoo...

Page 10: ...TABLE 1 EZ 3600 CEE 8...

Page 11: ...TABLE 2 EZ 3600 C 10...

Page 12: ...TABLE 2 EZ 3600 CEE 11...

Page 13: ...sket for CEE 39 111901186 Support 2500 C 8 111600694 Back tub ring assy 45 991173005 Screw 9 114900218 Rubber block 46 940018501 Washer 10 119200772 Cylinder cross bearing assy C CEE 47 995700014 Scre...

Page 14: ...TABLE 3 13...

Page 15: ...05474 Front panel soap dispenser for 1500 7 112605545 Front panel soap disp for 3600 C 7 112605546 Front panel soap disp for 2500 C 7 112605851 Front panel soap dispenser for CEE 8 112400414 Container...

Page 16: ...TABLE 4 15...

Page 17: ...ting 2500 C 5 112901946 Double pipe fitting 6 112400499 Soap dispenser housing 1500 6 112400503 Soap dispenser housing 2500 C 6 112400501 Soap dispenser housing 7 112400495 Water outlet dispenser 2500...

Page 18: ...TABLE 5 17...

Page 19: ...6 Heater housing 4 113300554 Heater housing for 2500 C 5 111901086 Impeller assembly 6 114200653 Gasket 7 113300547 Cover 7 113300553 Cover for 2500 C 8 116590714 Fan motor 9 186820052 Thermostat 10 1...

Page 20: ...TABLE 1 EZ 3600 C 7...

Page 21: ...ments are made with an ohmmeter When the test is concluded unplug the unit before replacing the connector on terminals 10 and 11 NOTE With the connector replaced on terminals 10 11 and power applied t...

Page 22: ...20 Testing the Drive Motor 7 and 10 pin connector...

Page 23: ...21...

Page 24: ...22 TIMER CHART...

Page 25: ...diagnose the problem and place the order for spare parts Tel 888 483 9627 4 To carry out repairs in a professional manner and in the fastest possible time after receiving parts 5 To invoice Equator fo...

Reviews: