background image

 

 

 

 

 

 

LOW TEMP WAREWASHERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X-32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical  Manual

 

 

 
 
 
 
 
 

2003 02

 

Summary of Contents for X-32

Page 1: ...LOW TEMP WAREWASHERS X 32 Technical Manual 2003 02...

Page 2: ...ion pertaining to our range of ware washerswill be coveredin this section Specific information on our current models are available uponrequest modelby model If you find any discrepancy or can t find c...

Page 3: ...l not be valid and therefore voids this warranty All authorized labor coverage shall be limited to regular hourly rates only Any supplemental hourly rates or charges such as weekends or emergency prem...

Page 4: ...Wash tank capacity 3 17 US gallon 12 liters Wash temperature 140F recommended Supply dependant no heaters Power supply 110 volts 60Hz 7 Amps peristaltic pumps for detergent sanitizer and Motor pump 0...

Page 5: ...WATER INLET A 3 4 NPT coupling is required with a maximum of 20 p s i dynamic pressure and a minimum of 18 p s i A water pressure regulator is required The water pressure should be 20 p s i Incoming...

Page 6: ...ELECTRICAL Unit must be connected with a 110 volts 60Hz line The terminal block will receive L1 N and Ground wire Unit must be well grounded Breaker rating should be 15 amps...

Page 7: ...do find any traces of damage contact the transport company that brought the dishwasher to your place at once A damage claim must be made immediately with the carrier Please assure that the following i...

Page 8: ...e additive To prime the pumps you must complete two full wash cycles You can adjust the amount injected by turning the white screw on the chemical pump Installation Check List Is the dishwasher connec...

Page 9: ...to 83 the drain pump MPS is operating At this time the cycle has ended and the drain pump only is operating from 83 to 99 and automatically the dishwasher is ready to start again 3 The black SQUARE pu...

Page 10: ...d valve EC Fill solenoid valve MPD Detergent pump MPB Rinse additive pump MPSA Sanitizer pump MP Door switch TLS Deliming option switch CRP Contact from relay MT Timer motor M1 M2 M3 M4 M5 Timer conta...