FLANGE ALIGNMENT TOOLS
OPERATOR INSTRUCTION MANUAL
PAGE 22
7.
Connect the hydraulic pump to the
hydraulic hose, and the hose to the
hydraulic adjusting cylinder.
Prime the pump until the joint
comes into alignment.
8.
Once in alignment the bolts may
be inserted and tightened.
After replacing all of the bolts (apart
from the bolt which will go into the
bolt-hole in which the FA9TE is
located), remove the tool by
reversing steps 2 - 4.
Insert the last bolt and tighten.
Care
should be taken not to drop any of the component parts when
removing them from the flange joint. This action will prevent injuries to
either the operator’s lower limbs, or to passers-by.