EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: [email protected]
Genie GEN-5 Series
Installation Manual
REV 2.0
24/09/2020
Model6253 OverWatch
™
Installation Manual
Document # DO001235
|
11 of 24
|
3.
Ground Connection:
Solder the Black Ground
wire from the
OverWatch
™
ECU Harness
to the White wire
(Ground) from the main
connector.
4.
Power Connection:
Install the Red wire from
the OverWatch
™
ECU
harness to the E-stop
switch connector terminal
1.