Installation Instructions
Start-up
Test Operation
System Checks
Indoor Unit
Outdoor Unit
Perform test operation after completing gas leak and electrical safety check.
1.Turn on electrical disconnect to outdoor unit.
2.Push the “ON/OFF” button on Remote Controller to begin testing.
3.Push MODE button, select COOLING, HEA
TING, FAN mode to confirm all functions.
1.Conceal refrigerant pipes where possible.
2.Make sure drain hose slopes downward along entire length.
3.Ensure all refrigerant pipes and connections are properly insulated.
4.Fasten pipes to outside wall, when possible.
5.Seal and weatherproof wall hole which the interconnecting wires and refrigerant pipes pass through.
1.Do all Remote controller’s buttons function properly?
2.Do the display panel lights work properly?
3.Does the swing louver function properly?
4.Does the drain work?
1.Push the mode button to COOL and adjust the room setting to 61
deg. wait up to 3 minutes
from compressor time guard. Does compressor and outdoor fan turn on in cooling mode?
2.Push the mode button to HEAT and adjust the room setting to 85
℉(
30
℃)
deg. wait up to 3 minutes
for compressor time guard. Does compressor and outdoor fan turn on in heat mode?
℉(
16
℃
)