UHF Transceiver Module TRX916 User
Manual
V
1.0
eQ-3 Limited
Page : 7 of 12
8 Operating
Conditions
The operating conditions of the TRX916 are listed in the table below.
Parameter Min
Typ
Max
Unit Condition
Operating temperature -20
55
°C
Supply voltage
1.8
3.6
V
All pins must have the
same voltage
Frequency 916.47
916.50
916.53
MHz
Data rate
10
kbit/s
FSK deviation
±
19
kHz
9
RF Receive Section
T
A
= 25 °C, VCC = 3.0 V if nothing else stated.
Parameter Min
Typ
Max
Unit Condition
Receiver sensitivity
-104
dBm
Saturation
-15
dBm
Current consumption
16
mA
Receive mode
Current consumption
100
µA
Wake On Radio mode
10
RF Transmit Section
T
A
= 25 °C, VCC = 3.0 V, if nothing else stated.
Parameter Min
Typ
Max Unit Condition
Output power / Field
strength
93.9
dBµV/m @ 3 m
Harmonics
53.9
dBµV/m
@
3m
Current consumption
17
mA