background image

Epygi Technologies    

 

 

                                                  Configuring Quadro with ISDN

 

 

The Bearer Establishment Procedure drop down list allows to select the session 

initiation method on the B channels. One of the following possibilities of the 

transmission path completion prior to receipt of a call acceptance indication can be 
selected:  

-

 

on channel negotiation at the destination interface;  

-

 

on progress indication with in-band information;  

-

 

on call acceptance.  

 

The  Calling Party Type of Number drop down list allows to select the type 

identifying the origin of call.  

 

The  Called Party Type of Number drop down list allows to select the type 

identifying the sub address of the called party of the call.  

 

The  Called Party Numbering Plan and Calling Party Numbering Plan drop 

down lists indicates correspondingly the numbering plan of the called party's and 
calling party's number.  
Incoming Called Digits Size text field indicates the number of received digits (in 
a range from 0 to 255) required to establish a call. When field has 0 value, system 

uses either timeout defined in the T302 field or the Sending Complete Information 
element messages to establish a call. Independent on the value in this field, 

Sending Comple

 

te Information element and pound sign always cause the call 

 

 IP checkbox selection will generate the 

 

. Otherwise, if CLIR service is 

 

elected, Quadro's user may hear a busy tone 

when peer has been disconnected.  

10.

alls over ISDN. Disabling one the channels 

11.

ured settings and press Finish to apply configuration values 

and leave the ISDN Wizard

 

5.2

 

 

numbers to different destinations (like local extensions, FAX modems, Auto Attendant, 

tc).  

establishment.  
The  Generate Progress tone on

progress tone to IP (H.323 or SIP).  
The  Enable CLIR Service checkbox selection enables Calling Line Identification 

Restriction (CLIR) service which displays the incoming caller ID only in case if 
Presentation Indication is allowed on the remote side

disabled, caller ID will be unconditionally displayed.  
When  Alternative Disconnection Mode checkbox is not selected, Quadro will 

disconnect the call as soon as disconnect message has been received from the 

peer, otherwise, when checkbox is s

 

 

Enable/disable  B1 and B2  channels for the voice transfer, according to ISDN network 
design requirements. Enabling both B1 and B2 channels, two parallel voice channels will 

be activated, which will allow two simultaneous c
will limit the number of simultaneous calls to 1.  

 

 

Press Next to move to the last page of the ISDN Wizard. All configured values are printed 

on this page. Verify the config

ISDN trunk configuration using MSN 

One of the big advantages of ISDN over an analogue service is the ability to assign multiple

phone numbers to one line.  This is implemented using Multiple Subscriber Numbering (MSN). 
 

The MSN service is provided by the ISDN service provider and allows to have several phone 
numbers for a single ISDN line. For example, if your ISDN ISP gives a range of numbers like 

810 3500, 810 3501,…, 810 3509, with the help of MSN service, it is possible to assign each of 
these 

e
 

To configure Quadro’s ISDN trunk using MSN, following configuration needs to be done: 

 

                PAGE 8  

                          7-Feb-06 

Summary of Contents for Quadro Quadro 16xi

Page 1: ...ion Template NEWSupportTemplate dot Last saved 2 7 2006 12 00 00 PM Abstract This document helps to configure and use the Quadro via ISDN interface and describes the basic configuration steps to setup...

Page 2: ...2 Functional Description 3 3 The Rear Panels of Quadro2xi 4xi and 16xi 3 4 Quadro s Front Panel LEDs 4 5 How to configure ISDN Trunk s 4 5 1 ISDN trunk configuration using DDI 5 5 2 ISDN trunk config...

Page 3: ...and one D channel signaling data transfer The BRI B channel service operates at 64 kbps and is meant to carry user data the BRI D channel service operates at 16 kbps and is meant to carry control and...

Page 4: ...tact your ISDN ISP administrator to get the ISDN Trunk configuration details Note that some ISDN ISPs may require the MSN configuration Perform following steps to configure the ISDN trunk s on the Qua...

Page 5: ...ed when lines are connected to a PBX to allow incoming calls to be routed directly to an extension by dialling the appropriate number This is instead of the caller having to dial a switchboard operato...

Page 6: ...t outgoing MSN text field when placing outgoing calls toward the CO 6 The Default outgoing MSN text field requires the Quadro identification number that should be registered and recognized at the CO f...

Page 7: ...already received from the destination but call confirmation ALERT CONNECT DISC or PROGRESS is not yet arrived The Alert Guard Timeout requires the value for the Alert Guard Timer in milliseconds nume...

Page 8: ...to apply configuration values and leave the ISDN Wizard 5 2 numbers to different destinations like local extensions FAX modems Auto Attendant tc establishment The Generate Progress tone on progress t...

Page 9: ...e of ISDN Wizard leave the Enable DDI Service checkbox unselected e TEI Mode configuration according to your ISDN provider s requirements The Automat mode requires ISDN connection to be established on...

Page 10: ...o ISDN bus this selection should be selected if any other devices ISDN PBX PCI card FAX I the network 7 MSN Service ed to ISDN bus table press the MSN Service defined SDN phone etc are connected to th...

Page 11: ...printed on this page Verify the configured settings and press Finish to apply configuration values 6 F correct source information acceptable by the ISDN provider For es see ISDN trunk and leave the I...

Page 12: ...nt by the configured IP address and the administrator s login Go to Telephony Call Routing and press Local Routing Table link to reach th Call Routing table The list of available call routes will be d...

Page 13: ...rd Page 2 6 t Leave AA guration th 7 Press Fig 14 C For this certain routing rule select Any Port from the Port ID drop down lis A Required and Fail Reason selections default for this particular confi...

Page 14: ...ISDN Trunk0 from Port ID drop down list insert 11 26 into the Inbound Caller Pattern text field and 56834 in the Inbound Prefix text field Choose PBX from Inbound Call Type drop down list With this r...

Page 15: ...calls selectively by the first available ISDN Trunk The caller s information sent to the ISDN CO for all extensions will be 5554645 this is one of the numbers provided by ISDN provider Some ISDN provi...

Page 16: ...he Inbound Caller Pattern te in the Inbound Call Type drop down list With this route all incoming calls not matching to any In the described example ro are for incoming ISDN calls The routes with iden...