4.2.8 Panel Board Removal
1. Release the Carriage Lock. (See Section 4.2.1.)
2. Remove the Document Cover. (See Section 4.2.2.)
3. Remove the Upper Housing. (See Section 4.2.3.)
4. Remove the screw (gold, CBS, M3x4).
5. Disconnect the locking connector (pull and release) for the Panel
Board from the Power Supply Board, and then remove the Panel
Board.
Figure 4-30. Panel Board Removal
C H E C K
P O I N T
In the following steps, manually move the carriage
back and forth slowly if necessary.
Connector
Panel Board
CBS Screw (M3x4)