WF-C20590 Installation Guide
Installing the Optional Units
37
21. After aligning the Bridge Unit with the printer, check the following:
22. Push the Bridge Unit into the printer to connect them.
0.12 in (3 mm)
or less
The gap between the bottom of the EJ Unit
cutout and the bottom of the Bridge Unit paper
insertion portion must be 0.12 in (3 mm) or less.
(Depending on the flooring of the installation site,
the printer may sink and cause a gap larger than
0.12 in [3 mm]. In this case, adjust the height by
adjusting the casters [see
Step 27
].)
Joint Hook Guide Pin
NG
NG
OK
The tip of the Joint Hook Guide Pin must touch the upper
edge of the Cutout of the Bridge Unit.
C H E C K
P O I N T
When performing this step, you should feel slight resistance
because the Bridge Unit plate makes contact with the tip of
the Joint Hook Guide Pin. If you do not feel resistance, the
Bridge Unit height may be too high. Check the points in
Step
21
again.
Put your
hands here
PRELIMINARY