85
Chapter 5 TM-DT Software System Development
5
Settings - Web Service settings - Serial communication Device
Performs the settings for serial communication devices controlled by TM-DT Software.
You can set the serial communication devices when you have set [Enable] under [Device control] in the
tings - Web service settings - Startup settings" on page 82
Item
Description
S erial communication
devices to be registered
Device ID
Set the device ID.
Port
Serial port on the rear of the product.
Select COM1 or COM2.
Control script
Set the device control script for controlling the serial communication
device.
Register device control scripts as necessary.
"Settings - Web service settings - Control script - Add/
Communication
speed (bps)
Set the device communication speed.
Data bit
Set the data bit.
Parity
Set the parity.
Stop bit
Set the stop bit.
Flow control
Set the flow control.
Add
Registers the serial communication device on this product.
Registered serial
communication devices
Displays a list of registered serial communication devices.
Detailed display
Displays the device settings confirmation window.
Operating test
Performs an operating test for a registered serial communication device.
1. Click to display the "Operating Test" window.
2. Enter a value and click [Send].
3. Confirm that correct operation is performed.
Delete
Deletes a registered serial communication device.