Confidential
EPSON
TITLE
SHEET
REVISION
NO
SHEET
NEXT
81
82
A
TM-T81
Specification
(STANDARD)
<Function 12>
GS ( E
p
L
p
H
fn a
(
fn
= 12)
[Name]
Transmit the configuration item for the serial interface
[Format] ASCII GS
( E
p
L
p
H
fn a
Hex 1D
28
45
p
L
p
H
fn a
Decimal 29 40 69
p
L
p
H
fn a
[Range] (
p
L
+
p
H
×
256) = 2 (
p
L
= 2 ,
p
H
= 0)
fn
= 12
a
= 1
[Description]
•
Transmits the configuration item for the serial interface specified by
a
.
a
Configuration item
1 Transmission
speed
GS ( H
p
L
p
H
fn [parameters]
[Name]
Request transmission of response or status
[Description]
•
Various processes are performed for the response.
•
p
L
,
p
H
specify (
p
L
+
p
H
×
256) as the number of bytes after
p
H
(
fn
and
[parameters]
).
•
fn
specifies the function.
•
[parameters]
specify the process of each function.
fn
Format
Function
No.
Function name
48
GS ( H
p
L
p
H
fn m d1 d2 d3 d4
48
Set the process ID response.
[Note]
•
Do not use this command in a system that uses the printer with the OPOS driver or
the JavaPOS driver provided by Seiko Epson Corporation.
<Function 48>
GS ( H
p
L
p
H
fn m d1 d2 d3 d4
(
fn
= 48)
[Name]
Set the process ID response
[Format] ASCII GS
( H
p
L
p
H
fn m d1 d2 d3 d4
Hex 1D
28
48
p
L
p
H
fn m d1 d2 d3 d4
Decimal 29 40 72
p
L
p
H
fn m d1 d2 d3 d4
[Range] (
p
L
+
p
H
×
256) = 6 (
p
L
=6 ,
p
H
= 0)
fn
= 48
m
= 48
32
≤
d
≤
126
[Description]
•
Saves the process ID specified by (
d1
,
d2
,
d3
,
d4
) for the data processed just before
this function.