Confidential
EPSON
TITLE
SHEET
REVISION
NO
SHEET
NEXT
59
60
A
TM-T81
Specification
(STANDARD)
DLE DC4
fn a b
(
fn
= 2)
[Name]
Execute power-off sequence
[Format] ASCII DLE
DC4
fn a b
Hex 10
14
fn a b
Decimal 16 20
fn a b
[Range]
fn
= 2
a
= 1
b
= 8
[Description]
•
Executes the printer power-off sequence and transmits the power-off notice.
•
Stores the values of the maintenance counter.
•
Sets the interface to BUSY.
•
Sets the printer to standby mode.
[Notes]
•
Take the following into consideration:
•
If the received data includes a data string matching this command, the printer
performs the command. Users must consider this.
For example: Graphic data might accidentally include a data string matching this
command.
•
Do not embed this command within another command.
For example: Graphic data might include this command.
•
This command does not shut the power off. The operator must turn off the power
after receiving the power-off notice.
•
If this command is encountered, the printer will not continue to process anything. To
recover the printer to print again, it is necessary to turn the power on again or execute
a hardware reset.
[Reference] Appendix
G