124
Appendix
Starting and stopping
Bluetooth
low energy technology Advertising
Format: cmd 0x08 0x000A n
Function: Starting and stopping transmission of the Advertising packet.
Device address specifications
Format: cmd 0x08 0x0005 n6 n5 n4 n3 n2 n1
Function: Specify a BD Address. Specify a value in Little Endian.
Bluetooth
low energy technology Advertising parameter specifications
Format: cmd 0x08 0x0006 aL aH bL bH c d e f1 f2 f3 f4 f5 f6 g h
Function: Sets a variety of parameters for the Advertising packet.
See the
Bluetooth
specifications for details.
Parameter n
Length
Function
00
2 characters
Advertising stop
01
2 characters
Advertising start
When specifying a start point, make sure you start Advertising using this command before
low energy technology Advertising Packet specifications" on page 125
As a Random Static Address is used in TM-m30II-H, bit7 and bit6 for n1 need to be set to 1.
Definition
Length
Default
Description
Min advertising Interval
2 bytes
aL: a0
aH: 00
00a0h * 0.625 = 100ms Period
00a0h is the minimum that can be
specified.
Max advertising Interval
2 bytes
bL: a0
bH: 00
00a0h * 0.625 = 100ms Period
00a0h is the minimum that can be
specified.
Advertising type
1 bytes
c: 03
03h: ADD_NONCONN_IND
Own address type
1 bytes
d: 01
01h: random device address
Peer address type
1 bytes
e: 00
00h: public device address
Peer address
6 bytes
f1-f6: 00
No use
Advertising channel map
1 bytes
g: 07
07h: All channel enabled
Advertising filter policy
1 bytes
h: 02
02h: Process scan requests from all
devices and only connection requests
from devices that are in the White List.